English
Language : 

URF_LP-20WR3_15 Datasheet, PDF (3/6 Pages) MORNSUN Science& Technology Ltd. – DC/DC Converter
DC/DC Converter
URF_LP-20WR3 Series
Weight
Cooling method
A4S rail package
Horizontal package/A2S wiring package/A4S rail package
76.00*31.50*25.80 mm
24.00g/46.00g/66.00g (Typ.)
Free air convection
EMC Specifications
CE
EMI
RE
ESD
RS
EFT
EMS
Surge
CS
Immunities of voltage dip,
drop and short interruption
CISPR22/EN55022 CLASS A (Bare component)/
CLASS B (see Fig.3-② for recommended circuit)
CISPR22/EN55022 CLASS A (Bare component)/
CLASS B (see Fig.3-② for recommended circuit)
IEC/EN61000-4-2 Contact ±4KV
IEC/EN61000-4-3 10V/m
IEC/EN61000-4-4 ±2KV (see Fig.3-① for recommended circuit)
IEC/EN61000-4-5 ±2KV (see Fig.3-①for recommended circuit)
IEC/EN61000-4-6 3 Vr.m.s
IEC/EN61000-4-29 0-70%
perf. Criteria B
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria A
perf. Criteria B
Product Characteristic Curve
Temperature Derating C urve
1 20
1 00
80
60 Safe Operating Area
40
20
0
-40
0
4055 85 120
Operat ing Temperat ure(℃)
Fig. 1
Design Reference
1. Typical application
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.
2015.08.12-A/2
Page 3 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation