English
Language : 

TA100W-EX-11 Datasheet, PDF (3/5 Pages) MORNSUN Science& Technology Ltd. – ULTRA-THIN ANALOG SIGNAL OUTPUT DETECTION SAFETY BARRIER
OTHER CHARACTERISTICS
Ambient Temperature
Operating temperature range:-25~+71℃
Transport and storage temperature:- 40~+85℃
Package
35mm DIN-rail package: T-rail card package (DIN50022), pluggable connection pin, thickness 12.50mm
Safety Class
IP20(IEC60529 / EN60529)
Weight
1 input 1 output: about 100g;1 input 2 output: about 128g
CONNECTION
1. Connection used dismountable terminals;
2. Cross section area of wiring: 0.5mm2 ~2.5 mm2;
3. The length of bare wire is about 8mm, locked up by the M3 bolt.
Selection guidelines for intrinsically safe explosion protection system
1.The explosion protection grade of the barrier must be not less than that of intrinsically safe explosion protection device in spot.
2.Take inconsideration of hazardous end output resistance and loop resistance make sure the barrier output voltage meets the minimum
operation voltage requirement of intrinsically safe device in spot.
3.The safety parameters about intrinsically safe end meets:
Uo ≤ UI, Io ≤ Iin, Po ≤ Pin
Cc ≤ Co-Ci, Lc ≤ Lo-Li
4.Select suitable safety barrier which matches the intrinsically safe device in spot according to the power polarity, signal type and transmission
mode about the device.
5.Much more protection is required, which can avoid the influence of the leakage current generated by safety barrier on intrinsically safe device
in spot.
6. The wires leading to dangerous field should be constrainted in blue intrinsically safe wires, and its copper cross-section should be more than
0.5mm2; Insulation intensity should be more than 500VDC.
Operation notes
1. Please do not use this product in hazardous area.
2. The power supply of this product should be 24VDC power source. It is forbidden to use 220VAC power supply.
3. To avoid invalid explosion protection function, or any failure, users disassemble this product is forbidden.
APPLICATION CIRCUIT DIAGRAM & PIN DESCRIPTION
PIN
1
2
3
8 Inside
7 Outside
Inside 6
4
Outside
5
5
1 0 Inside
9 Outside
1 2 Inside
1 1 Outside
Inside 4
6
Outside 3
7
8
Inside 2
Outside
9
1
10
11
12
TAx4x-EX
NC
NC
Signal input-
Signa linput+
NC
NC
Signal 1 output-
Signal 1 output+
Signal 2 output-
Signal 2 output+
Power Input-
Power Input+
Bottom power supply port
Note: When use bottom power supply, anyone group or both is OK.
Pins 1, 2, 3, 4, 5, and 6 are in the field area, belong to the dangerous
side, use blue terminals;
Pin 7, 8, 9, 10, 11 and 12 are in the control area, belong to the safe
side, use green terminals
PIN TAx05W-EX
1 Signal input-
2 isolated output -
3 Signal input+
4 isolated output+
5 NC
6 NC
7 Signal 1 output-
8 Signal 1 output+
9 Signal 2 output-
10 Signal 2 output+
11 Power Input-
12 Power Input+
TAx00W-EX(TAx02W-EX)
NC
NC
Signal input+
Signal input-
NC
NC
Signal 1 output-
Signal 1 output+
Signal 2 output-
Signal 2 output+
Power Input-
Power Input+
The copyright and authority for the interpretation of the products are reserved by MORNSUN TAxxxW-EX-xx
2013.12.27-A/0 Page 3 of 5