English
Language : 

LO10-26DX512-04 Datasheet, PDF (3/5 Pages) MORNSUN Science& Technology Ltd. – AC-DC converter for electric meters
20.0
17.5
15.0
12.5
11 .0
10.0
7.5
5.0
2.5
0
-25 0 10 20 30 40 50 60 70 80
Environment Temperature(℃)
Figure 3: Output Power V.S. Environment Temperature
20.0
17.5
15.0
12.5
11.0
10.0
7.5
5.0
2.5
0
90 100 120
150
200
600
650
Input Voltage(Vdc)
Figure 4: Output Power V.S. Input Voltage
PARALLEL LINES MEASURE
Fuse
L
1
+Vo
AC-DC
C1
C2
Copper sheet
Load
N
2
TYPICAL APPLICATIONS
-Vo
25.4m m
25.4m m
C1: 10μF
C2: 0.1μF
Co nnect Oscillo gra ph Pro be
L
L
+ C1 C2 TVS RL
Vo1
-
+
L/N
Vo2
N
- C3 C4
RL
THREE-PHASE CIRCUIT APPLICATION
Remark:
Output filtering capacitors C1,C3 is electrolytic capacitors, It is
recommended to use high frequency and low impedance electrolytic
capacitors. Recommended value (C1:220µF/10V; C3: 100µF/25V); C2, C4
are ceramic capacitors and they used to filter high frequency noise,
Recommend value:0.1µF/50V , It is recommended that the 5.3V main
output circuit adds TVS to protect post-circuits (if converter fails),;and the
12.6V main output circuit has had TVS inside so it needs no external TVS.
Win di ng resistor
Win di ng resistor
Wi nd in g resi sto r
LO10-26DX512-04
Three-phase-four-wire full-wave rectification application
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LO10-26DX512-04 A/1-2012
Page 3 of 5