English
Language : 

B0305T-W2 Datasheet, PDF (3/4 Pages) MORNSUN Science& Technology Ltd. – DC/DC Converter
DC/DC Converter
B_(X)T-W2 Series
Design Reference
1. Typical application
If it is required to further reduce input and output ripple, a filter capacitor can be connected to the input and output terminals, see Fig.3.
Moreover, choosing suitable filter capacitor is very important, start-up problems may be caused by too large capacitance. To ensured the
modules running well, the recommended capacitive load values as shown in Table 1.
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear regulator and an capacitor filtering
network with overheat protection that is connected to the input or output end in series (see Fig.4)
Vin
C in
GND
DC DC
Fig.3
+Vo
C out
0V
Vin
REG
REG
+Vo
DC DC
GND
0V
Fig.4
Recommended capacitive load value table (Table 1)
Vin(VDC)
3.3/5
12
24
--
--
Cin(μF)
4.7
2.2
1
--
--
Vo (VDC)
3.3/5
9
12
15
24
Cout(μF)
10
4.7
2.2
1
0.47
2. Output load requirements
To ensure the module work efficiently and reliably, during the operation, the min. output load should be no less than 10% of the full load. If
the actual output power is low, please connect a resister to the output terminal in parallel, with a recommenced resistance which is 10% of
the rated power, and derating is required during operation.
3. For more information please find the application notes on www.mornsun-power.com
Dimensions and Recommended Layout
2014.05.22-B/2
Page 3 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation