English
Language : 

URH2405P-6WR3_15 Datasheet, PDF (2/4 Pages) MORNSUN Science& Technology Ltd. – DC/DC Power Supply Module
DC/DC Power Supply Module
URH_P-6WR3 Series
Transient Recovery Time
Transient Response Deviation
25% load step change
--
300
500
μs
--
±3
±5
%
Temperature Drift Coefficient
Full load
--
--
±0.03
%/℃
Ripple& Noise*
20MHz bandwidth
--
100
180
mVp-p
Over-current Protection
110
150
260
%Io
Over-voltage Protection
Short circuit Protection
Input voltage range
110
--
160
%Vo
Continuous, self-recovery
Note: * Ripple and noise tested with “parallel cable” method, oscilloscope using the 1X probe, please see DC-DC Converter Application Notes for specific
operation methods.
General Specifications
Item
Insulation Voltage
Insulation Resistance
Operating Conditions
Min.
Typ.
Input-output, with the test time of 1 minute and the
leak current lower than 1mA
6000
--
Input-output, insulation voltage 500VDC
10000
--
Max.
--
--
Unit
VDC
MΩ
Isolation Capacitance
Input-output, 100KHz/0.1V
--
13
20
pF
Transformer creepage
5.0
--
--
Enhanced isolation
Transformer clearance
PCB creepage & clearance
2.4
--
6.0
--
--
mm
--
Optocoupler creepage
6.0
--
--
Operating Temperature
Derating if the temperature is ≥71℃ (see Fig. 1)
-40
--
85
℃
Storage Humidity
Without condensation
5
--
95
%RH
Storage Temperature
Lead Temperature
Vibration
Welding spot is 1.5mm away from the casing, 10
seconds
-55
--
125
℃
--
--
300
10-55Hz, 10G, 30 Min. along X, Y and Z
Switching Frequency*
PWM mode(nominal, full load)
--
300
--
KHz
MTBF
MIL-HDBK-217F@25℃
1000
--
--
K hours
Note:* This series of products using reduced frequency technology, the switching frequency is test value for full load, When the load is reduced to below 50%, the
switching frequency decreases with decreasing load.
Physical Specifications
Casing Material
Package Dimensions
Weight
Cooling method
Black flame-retardant and heat-resistant plastic (UL94-V0)
31.60*20.30*10.20 mm
13g(Typ.)
Free air convection
EMC Specifications
EMI
CE
ESD
EFT
EMS
Surge
CS
Immunities of voltage dip,
drop and short interruption
CISPR22/EN55022 CLASS A (Bare component)
IEC/EN61000-4-2 Contact ±6KV
IEC/EN61000-4-4 ±2KV (see Fig.3-① for recommended circuit)
IEC/EN61000-4-5 ±2KV (see Fig.3-①for recommended circuit)
IEC/EN61000-4-6 3 Vr.m.s
IEC/EN61000-4-29 0-70%
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria A
perf. Criteria B
2015.04.16-A/2
Page 2 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation