LO05-00B05E Datasheet, PDF (2/4 Pages) MORNSUN Science& Technology Ltd. – 5W, AC-DC switching power supply | |||
|
◁ |
Input variation
Load variation (0%-100%)
Single Output
Dual Output
Single Output
Dual Outputï¼balance loadï¼
±2%
±2%ï¼Main outputï¼
±5%ï¼Supplement outputï¼
±2%
±2%ï¼Main outputï¼
±5%ï¼Supplement outputï¼
Minimum Load
Output low ripple & noise
ï¼p-pï¼
Max capacitive load
(20MHz bandwidth )
2200μF
Single Output
Dual Output
0
50mV typ.
75mV typ.
100mV max.
150mV max.
Short circuit protection
Over current protection
Continuous auto-recovery
Single Output
Dual Output
105%ï½200% Io auto-recovery
â§120% Io auto-recovery
Output over voltage protection
Single Output
Dual Output
6.8V TVS clamp
Main output 18V TVS clamp
Note:
1. Test ripple and noise by âparallel cableâ method.
2. Dual output models, when one of the outputs triggers on OCP, both of the output voltages will decrease and turn into hiccup mode. Output voltage
will becom e normal when fault is eliminated.
COMMON SPECIFICATIONS
Temperature
Operating temperature
Storage temperature
Humidity & Altitude
Operating humidity & altitude
Storage humidity & altitude
Temperature drift
Switching Frequency
Delay time
Hold-up time
I/O-isolation voltage
Isolation resistance
Isolation voltage
(Leakage current 10mA)
Electrostatic discharge
Electrical fast transient
EMC compliance
Surge
Radio frequency magnetic field
Mechanical properties
Power-frequency magnetic field
Voltage dips, short interruptions
and voltage variations immunity
Vibration
Impact
Safety class
Install
Cooling
MTBF
Weight
-10ï½+70â (Power derating above 50 â)
-25âï½+75â
5%-85% ï¼no dewing in deviceï¼ï¼3000m
5%-95% ï¼no dewing in deviceï¼ï¼9000m
<±0.02%/âï¼Main outputï¼ <±0.06%/âï¼Supplement outputï¼
60kHz
<1s
20ms(typ.) @Vin=220VACï¼Rated load
>100 MΩ @ 25âï¼45-70%Rhï¼500VDC
Input-ground : 2KVAC/1Min: Output-ground:1KVAC/1Min:
Input-Output : 2KVAC/1Min; Output-Output:500VAC/1Min.
IEC 61000-4-2
4kVï¼t ouchï¼8kVï¼air ï¼
IEC 61000-4-4
level 4
IEC 61000-4-5
level 4
IEC 61000-4-3
level 4
IEC 61000-4-8
IEC 61000-4-11
level 4
Short interruptions 0% 0.5 cycle
Voltage dips 70% 10 cycle
GB/T2423.10-2008
GB/T2423.5-1995
CLASS I
PCB
Free air convection
>300,000h @25â
about 50 g
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
L005 series
A/0-2011
Page 2 of 4
|
▷ |