English
Language : 

G0505S-2WR2 Datasheet, PDF (2/5 Pages) MORNSUN Science& Technology Ltd. – SIP package
DC/DC Converter
G_S-2WR2 & H_S-2WR2 Series
Input Specifications
Item
Input Current (no-load/full load)
Surge Voltage (1sec. max.)
Reflected Ripple Current
Input Filter
Operating Conditions
5V input
12V input
24V input
5V input
12V input
24V input
Min.
Typ.
Max.
--
35/520
80/--
--
15/217
40/--
--
10/106
25/--
-0.7
--
9
-0.7
--
18
-0.7
--
30
--
0.2
--
Capacitor filter
Unit
mA
VDC
A
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Output Voltage Accuracy
See tolerance envelope graph (Fig. 1)
Line Regulation
Input voltage change: ±1%
--
--
±1.2
--
5VDC output
--
--
20
Load Regulation
10%-100% load
9VDC output
12VDC output
--
--
15
%
--
--
15
15VDC output
--
--
15
Ripple & Noise*
20MHz bandwidth
--
100
150
mVp-p
Temperature Drift Coefficient
100% full load
--
±0.02
--
%/℃
Output Short Circuit Protection**
--
--
3
s
Note: *Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
**Supply voltage must be discontinued at the end of short circuit duration which less than 3s.
General Specifications
Item
Operating Conditions
Isolation Voltage
Input-output, with the test time of 1 minute
Min.
Typ.
4200
--
6000
--
Max.
--
--
Unit
VAC
VDC
Patient Leakage Current
250VAC,50/60Hz
--
--
2
μA
Isolation Resistance
Input-output, isolation voltage 500VDC
1000
--
--
MΩ
Isolation Capacitance
Input-output, 100KHz/0.1V
--
5
--
pF
Operating Temperature
-40
--
85
Storage Temperature
Casing Temperature Rise
Ta=25℃
-55
--
125
--
25
--
℃
Pin Welding Resistance
Temperature
Welding spot is 1.5mm away from the casing, 10 seconds
--
--
300
Storage Humidity
Non-condensing
--
--
95
%
Switching Frequency
100% load, nominal input voltage
--
100
--
KHz
MTBF
MIL-HDFK-217F@25℃
3500
--
--
Transformer Creepage
5
--
--
Transformer Clearance
5
--
--
PCB Creepage & Clearance
5.5
--
--
Note:1、Patient leakage current and reinforced insulation is based on a 250 VAC, 50/60 Hz system input voltage.
2、The UL certification (ANSI/AAMI ES60601-1, File No. E347375) of G_S-2WR2 & H_S-2WR2 series is pending, G_S-2WR2 & H_S-2WR2 series meets
1xMOPP/2xMOOP when system input voltage is with 250VAC , 50/60Hz.
K hours
mm
Physical Specifications
Casing Material
Package Dimensions
Weight
Cooling Method
Black flame-retardant and heat-resistant plastic (UL94 V-0)
19.50*9.80*12.50 mm
4.2g(Typ.)
Free air convection
2016.03.07-A/0
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation