English
Language : 

F0503XT-2WR2 Datasheet, PDF (2/4 Pages) MORNSUN Science& Technology Ltd. – DC/DC Converter
DC/DC Converter
F_XT-2WR2 Series
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Output Voltage Accuracy
See tolerance envelope graph (Fig. 1)
Line Regulation
3.3VDC output
--
Input voltage change: ±1%
Other output
--
--
±1.5
--
--
±1.2
3.3VDC output
--
18
--
5VDC output
--
12
--
Load Regulation
10%-100% load
9VDC output
--
9
--
%
12VDC output
--
8
--
15VDC output
--
7
--
24VDC output
--
6
--
Ripple & Noise*
20MHz bandwidth
--
100
--
mVp-p
Temperature Drift Coefficient
100% load
--
--
±0.03
%/℃
Output Short Circuit Protection**
5/12/15VDC input
24VDC input
Continuous, self-recovery
--
--
1
s
Notes:
* Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
**For the products of 24V Intput voltage, supply voltage must be discontinued at the end of short circuit duration.
General Specifications
Item
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Operating Temperature
Storage Temperature
Casing Temperature Rise
Pin Welding Resistance Temperature
Reflow Soldering Temperature
Storage Humidity
Switching Frequency
MTBF
Operating Conditions
Input-output, with the test time of 1 minute and the leak
current lower than 1mA.
Input-output, isolationvoltage 500VDC.
Input-output, 100KHz/0.1V.
3.3V/5V
output
Other output
Derating if the temperature ≥71°C,
(see Fig. 2)
Derating if the temperature ≥85°C,
(see Fig. 2)
Ta=25℃
Welding spot is 1.5mm away from the casing, 10
d
Non-condensing
100% load, nominal input voltage.
MIL-HDFK-217F@25℃
Min.
Typ.
3000
--
1000
--
--
20
Max.
--
--
--
Unit
VDC
MΩ
pF
-40
--
105
℃
-55
--
125
--
25
--
--
--
300
Peak temp.≤245℃, maximum duration
time≤60s at 217℃.
For actual application, please refer to
IPC/JEDEC J-STD-020D.1.
--
--
95
%
--
100
300
KHz
3500
--
--
K hours
Physical Specifications
Casing Material
Package Dimensions
Weight
Cooling Method
Black flame-retardant heat-proof epoxy resin (UL94-V0)
12.70*11.20*7.25mm
1.5g (Typ.)
Free air convection
EMC Specifications
Conducted disturbance
EMI
Radiated emission
EMS
Electrostatic discharge
CISPR22/EN55022 CLASS B (see Fig. 4 for recommended circuit)
CISPR22/EN55022 CLASS B (see Fig. 4 for recommended circuit)
IEC/EN61000-4-2 Contact ±6KV perf. Criteria B
2014.05.22-A/1
Page 2 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation