English
Language : 

D050505S-2W Datasheet, PDF (2/2 Pages) MORNSUN Science& Technology Ltd. – TWIN OUTPUT DC-DC CONVERTER
OUTPUT SPECIFICATIONS
Item
Line regulation
Test conditions
For Vin change of 1%
Min Typ Max Units
±1.2
10% to 100% load(5V Output)
12.8 15
Load regulation
10% to 100% load(9V Output)
10% to 100% load(12V Output)
8.3 10 %
6.8 10
10% to 100% load(15V Output)
6.3 10
Output voltage accuracy
Temperature drift
100% full load
See tolerance envelope graph
0.03 %/°C
Output ripple& Noise* 20MHz Bandwidth
100 150 mVp-p
Switching frequency Full load, nominal input
70
KHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
2. See below recommended circuits for more details.
3. Operation under minimum load will not damage the converter; However, they may not meet all
specification listed, and that will reduce the life of product
TYPICAL CHARACTERISTICS
Operating Temp.(oC)
OUTLINE DIMENSIONS & PIN CONNECTIONS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
(Front View)
0.50[0.020]
19.60[0.772]
(Bo ttom Vie w)
12
45 67
2.54[0.100]
15.24[0.600]
∅1.00 [0.039]
12
4 56 7
Note: grid 2.54*2.54mm.
TUBE OUTLINE DIMENSIONS
9.60
[0.378]
FOOTPRINT DETAILS
Pin
F un c ti on
1
Vin
2
G ND
4
0V1
5
+ Vo1
6
0V2
7
+ Vo2
Note:
Unit:mm[inc h]
Pin section tolerances: ± 0.10mm[ ±0.004inch]
General tolerances:± 0.50mm[ ±0.020inch]
4.90 [0.193]
Note:
Unit :mm[inch]
General tolerances: ±0.50mm[±0.020inch]
L=530mm[20.866inch] Devices per tube quantity : 25pcs
L=220mm[8.661inch] Devices per tube quantity: 10pcs
Short tube inner packaging dimensions: L*W*H=255*170*80mm;
Short tube outer packaging dimensions(with six inner packaging boxes):
L*W*H=375*280*270mm;
Long tube inner packaging dimensions: L*W*H=580*200*100mm;
Long tube outer packaging dimensions(with two inner packaging boxe:s)
L*W*H=600*215*220mm;
Long tube outer packaging dimensions(with three inner packaging box:es)
L*W*H=600*215*325mm.
APPLICATION NOTE
Requirement on output load
To ensure this module can operate efficiently
and reliably, a minimum load is specified for
this kind of DC/DC converter in addition to a
maximum load (namely full load). During
operation, make sure the specified range of
input voltage is not exceeded, the minimum
output load could not be less than 10% of the
full load. If the actual output power is very
small, please connect a resistor with proper
resistance at the output end in parallel to
increase the load, or use our company’s
products with a lower rated output power.
Overload Protection
Under normal operating conditions, the output
circuit of these products has no protection
against over-current and short-circuits. The
simplest method is to connect a self-recovery
fuse in series at the input end or add a circuit
breaker to the circuit.
Recommended and testing circuit
If you want to further decrease the
input/output ripple, an “LC” filtering network may
be connected to the input and output ends of the
DC/DC converter, see (Figure 1).
L
L
Vin
Cin
GND
DC DC
Cout
L
Cout
(Figure 1)
+Vo1
0V1
+Vo2
0V2
It should also be noted that the inductance
and the frequency of the “LC” filtering network
should be staggered with the DC/DC frequency
to avoid mutual interference. However, the
capacitance of the output filter capacitor must be
proper. If the capacitance is too big, a startup
problem might arise. For every channel of
output, provided the safe and reliable operation
is ensured, the recommended capacitance of its
filter capacitor sees (Table 1).
EXTERNAL CAPACITOR TABLE (Table 1)
Vin
Cin
Vout
Cou
(VDC)
(μF)
(VDC)
(μF)
5
4.7
5
4.7
12
2.2
9
2.2
24
1
12
1
--
--
15
0.47
It’s not recommend to connect any external capacitor
in the application field with less than 0.5 watt output.
Output Voltage Regulation and Over-voltage
Protection Circuit
The simplest device for output voltage
regulation, over-voltage and over-current
protection is a linear voltage regulator with
overheat protection that is connected to the
input or output end in series (Figure 2).
Vo1
Vin
REG
0V1
GND
DC DC
Vo2
0V2
REG
Vo1
Vin
GND
0V1
DC DC
REG
Vo2
0V2
(Figure 2)
No parallel connection or plug and play.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
D_S-2W A/4-2012