English
Language : 

WRB1205LT-3WR2 Datasheet, PDF (1/6 Pages) MORNSUN Science& Technology Ltd. – SINGLE OUTPUT DC/DC CONVERTER
WRB_LT-3WR2 SERIES
3W,WIDE INPUT, ISOLATED & REGULATED
SINGLE OUTPUT DC/DC CONVERTER
Patent Protected RoHS
FEATURES
● Ultra-small size, SMD packag
● 2:1 wide input voltage range
● Operating temperature range:
-40°C ~ +85°C
● 1.5KVDC isolation
● Short circuit protection (automatic recovery)
● High power density
● Meet UL94-V0
PART NUMBER SYSTEM
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
SELECTION GUIDE
Model
Input Voltage(VDC)
Nominal
①
(Range) Max.
Output
Voltage
(VDC
W RB1205LT-3W R2
5
12
W RB1212LT-3W R2
22
12
(9-18)
W RB1215LT-3W R2
15
APPLICATION
The WRB_LT-3WR2 series are specially designed for
applications where a wide range input voltage power supplies
are isolated from the input power supply in a distributed power
supply system on a circuit board.
1) These products apply to where: Input voltage range≤2:1;
2) 1.5KV input and output isolation;
3) Regulated and low ripple noise is required.
Output Current (mA) Input Current (mA)(typ.)
Max.
Min.
@Max.
Load
@No Load
600
30
333
Reflected
Ripple
Current
(mA,typ.)
250
12
325
22
200
10
316
Max.
Efficiency
Capacitive (%, typ.)
Load(µF) @Max. Load
3300
75
1800
77
1000
79
W RB2405LT-3W R2
5
600
30
164
3300
76
24
W RB2412LT-3W R2
40
12
250
12
154
12
30
1800
81
(18-36)
W RB2415LT-3W R2
15
200
10
156
1000
80
W RB4805LT-3W R2
5
600
30
81
48
W RB4812LT-3W R2
80
12
250
12
78
8
(36-75)
W RB4815LT-3W R2
15
200
10
78
Note:①. Absolute maximum rating without damage on the converter, but it isn't recommended.
3300
77
1800
80
1000
80
INTPUT SPECIFICATIONS
Item
Test Conditions
12VDC input
Input Surge Voltage (1sec. max.) 24VDC input
48VDC input
12VDC input
Start-up Voltage
24VDC input
48VDC input
Input Filter
Min.
Typ.
Max.
Unit
-0.7
--
25
-0.7
--
50
-0.7
--
100
VDC
4.5
8
9
11
16
18
24
33
36
Pi Filter
OUTPUT SPECIFICATIONS
Item
Test Conditions
Output Voltage Accuracy
5% to 100% load
No-load Output Voltage Accuracy
Vo≤5V
Vo>5V
Line Regulation
Full load, Input voltage from low to high
Load Regulation
5% to 100% load
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Min.
Typ.
Max.
Unit
--
±1
±3
--
±1.5
±5
--
±1.5
±3
%
--
±0.2
±0.4
--
±0.2
±0.75
W RB_LT-3W R2
2013.03.12-A/1 Page 1 of 6