VRA2405LD-30WR2 Datasheet, PDF (1/7 Pages) MORNSUN Science& Technology Ltd. – DUAL OUTPUT DC-DC CONVERTER
VRA_LD-30WR2 SERIES
30W, WIDE INPUT, ISOLATED & REGULATED
DUAL OUTPUT DC-DC CONVERTER
FEATURES
● Efficiency up to 89%
● 2:1 wide input voltage range
● Operating temperature range:
-40°C ~ +85°C
● 1.5KVDC isolation
● Output short circuit , over current and over voltage
protection
● Meet CISPR22/EN55022 CLASS A
● Industry standard pinout
● Inverse polarity protection for A2S(chassis
mounting)and A4S(DIN-Rail mounting)
Patent Protected RoHS
PART NUMBER SYSTEM
VRA2405LD-30WR2
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
APPLICATION
The VRA_LD-30WR2 series offer 30W of output, with 2:1 wide input
voltage of 18-36VDC, 36-75VDC and features 1500VDC isolation, over
current and short-circuit protection etc, as well as six-sided metal
shielding. All models are particularly suited to industrial control, electric
power, instrumentation, tele-communications etc.
SELECTION GUIDE
①
Model Number
VRA2405LD-30WR2
Input Voltage (VDC)
Nominal
②
(Range) Max
Output
Voltage
(VDC)
±5
Output Current (mA) Input Current (mA)(typ.) reflection
Max.
Max.
Min.
@
Max.load
ripple Current Capacitor
@ No load (mA,typ.) Load (max,µF)
±3000 ±150
1460
120
20
±3000
③
Efficiency
(%, typ.)
@ Max. load
88
VRA2409LD-30WR2
±9
±1667
±83
1440
20
10
±470
88
VRA2412LD-30WR2
24
(18-36)
40
±12
±1250
±63
1440
20
10
±470
88
VRA2415LD-30WR2
±15
±1000
±50
1440
20
10
±470
89
VRA2424LD-30WR2
±24
±625
±32
1440
20
10
±300
89
VRA4805LD-30WR2
±5
±3000 ±150
730
80
20
±3000
88
VRA4812LD-30WR2
VRA4815LD-30WR2
48
(36-75)
80
±12
±1250
±63
720
±15
±1000
±50
720
20
20
10
10
±470
±470
89
89
VRA4824LD-30WR2
±24
±625
±32
720
20
10
±300
89
Note: ① series with suffix “H” are heat sink mounting, for example VRA2405LD-30WHR2. series with suffix "A2S" are chassis mounting, with suffix "A4S" are DIN-Rail
mounting, for example VRA2405LD-30WR2A2S is chassis mounting, VRA2405LD-30WR2A4S is DIN-Rail mounting. If the application has a higher requirement for
heat dissipation, you can choose modules with heat sink.
②Absolute maximum rating without damage on the converter, but it isn't recommended.
③The efficiency of "A2S" and "A4S" is approx. 2% lower for the protection of inverse polarity.
INPUT SPECIFICATIONS
Item
Test conditions
Min.
Typ.
Max.
Unit
Input Surge Voltage (1sec. max.)
Start-up Voltage
24VDC Input Models
48VDC Input Models
24VDC Input Models
48VDC Input Models
-0.7
--
50
-0.7
--
100
VDC
--
17.8
18
--
35.8
36
Under Voltage Shutdown
24VDC Input Models
48VDC Input Models
16
--
--
VDC
32
--
--
Start-up Time
Nominal input & constant resistance load
--
10
--
ms
The copyright and authority for the interpretation of the products are reserved by MORNSUN
VRA_LD-30WR2
2013.09.24-A/0
Page 1 of 7