English
Language : 

URB1D05XD-10W_15 Datasheet, PDF (1/5 Pages) MORNSUN Science& Technology Ltd. – DC/DC Converter
DC/DC Converter
URB1D_XD-10W Series
10W, ultra wide input isolated & regulated
output DC-DC converter
single
FEATURES
 Wide range of input voltage (4:1)
 Efficiency up to 86%
 Isolation voltage :1.5K VDC
 Operating temperature range: -40℃ to +85℃
 Output over-voltage protection, Short circuit
protection
 Low ripple & noise
 A2S (wring mounting) and A4S (35mm rail
mounting) products featuring anti-reverse
connection for input
 Meet EN60950, EN50155
 International standard pin-out
Patent Protection RoHS
URB1D_XD-10W series are isolated 10W DC-DC products with 4:1 input voltage .They feature efficiency up to 86%, 1500VDC isolation,
operating temperature of -40℃ ~+85℃ , output over-voltage protection,short-circuit protection. It offers good EMC performance, meet
EN60950 and EN50155 standards. All models are particularly suited to railway etc.c. And extension package A2S and A4S also enable them
with reverse voltage protection.
Selection Guide
certification
Part No.①
URB1D05XD-10W
Input Voltage (VDC)
Nominal
(Range)
Max.②
Output
Output Voltage
(VDC)
Output Current (mA)
(Max./Min.)
5
2000/100
Efficiency
③(%,Min./Typ.)
@ Full Load
79/81
Max.
Capacitive
Load(µF)
2200
EN60950
EN50155
URB1D12XD-10W
URB1D15XD-10W
40-160
(110)
170
12
15
833/42
667/33
83/85
220
83/85
100
URB1D24XD-10W
24
416/21
84/86
47
Note:
①series with suffix "A2S" are chassis mounting, with suffix "A4S" are DIN-Rail mounting, for example URB1D05XD-10WA2S is chassis mounting , URB1D05XD-10WA4S
is DIN-Rail mounting;
②Absolute maximum rating without damage on the converter, but it isn't recommended;
③The efficiency of "A2S" and "A4S" is approx. 2% lower for the protection of inverse polarity.
Input Specifications
Item
Input Current (full load / no-load)
Reflected Ripple Current
Input impulse Voltage (1sec. max.)
Starting Voltage
Input Filter
Hot Plug
Operating Conditions
Min.
Typ.
Max.
Unit
--
113/3
115/5
mA
--
30
--
-0.7
--
180
VDC
--
--
40
Pi filter
Unavailable
Output Specifications
Item
Operating Conditions
Min.
Output Voltage Accuracy
--
Line Regulation
Full load, the input voltage is from low voltage to
high voltage
--
Load Regulation
5%-100% load
--
Transient Recovery Time
--
25% load step change
Transient Response Deviation
--
Temperature Coefficient
Full load
--
Ripple&Noise*
20MHz bandwidth
--
Over-voltage Protection
110
Input voltage range
Short circuit Protection
Typ.
Max.
±1
±2
±0.2
±0.5
±0.5
±1
500
1000
±3
±5
--
±0.03
60
100
120
140
Continuous
Note: * Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
Unit
%
µs
%
%/℃
mV p-p
%Vo
2015.8.31-B/0
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation