TW147HL Datasheet, PDF (1/5 Pages) MORNSUN Science& Technology Ltd. – High linearity
Signal conditioning module
TW147HL Series
Two-wire loop power supply signal conditioning module
HART Signal Transmission is available
RoHS
PART NUMBER SYSTEM
TW147HL
封Pa装ck形ag式e
支HA持RTHASiRgTn协al议Transmission is available
配Ou电tp电ut压voltage of isolated
配Ou电tp电ut流current of isolated
输Sin入gle信I号 nput
输Sin入gle信I号 np类ut型type
产Pro品to标co识l
FEATURES
 Loop power
 High linearity (0.1% F.S.)
 High isolation voltage(2KVAC/1mA/60s)
 Compact size: SIP9 (26*9.5*12.5mm)
 Extremely low temperature coefficient:
50ppm/℃(TYP)
 Operating temperature range: -40°C ~
+85°C
 HART Signal Transmission is available
 ESD protection(Bare component ±4KV)
TW147HL is a specific signal conditioning module for smart field instruments with HART, The isolation module is designed for transmitting the
PWM input signal to output isolated standard 4~20mA through output loop-powered .Meanwhile the module can offer a isolation
micro-power for the pre-devices. The module also has an integrated HART signal channel. according to the recommended solutions, it can
realize the Half duplex communication between the field and control area. which greatly reduce the wiring cost between the field and the
control area.
The module adopts unique electromagnetic isolation mode and high performance power feedback. The module achieves the function
of transmitting PWM signal to isolated standard 4~20mA accurately, which can match instruments analog input port(such as PLC , DCS ,
etc).
In addition, this module has small package (SIP9) and excellent temperature drift characteristics (at -40 ℃ ~ +85 ℃ operating
temperature range drift is less than 50PPM / ℃). This module can bear 2KVAC isolation voltage between the input and output.
Selection Guide
Part No.
Power Supply input Typ.
(VDC)
TW147HL
10~24
Notes: Customization products are available if required.
Input Signal(Duty Cycle)
0~100%
Output Signal(mA)
4~20
Isolation Power Output
(VDC)
3.3
Input Specifications
Item
Input voltage
Power Input
Input power
Power supply protection
Frequency
Single Input
Duty Cycle
Edge time
PWM amplitude
Overload
Operating Conditions
Min.
10
Single Input and Isolation power
output at full load
--
Operating temperature range of -40
to +85℃,ViH-ViL=3.3V
100
Operating temperature range of -40
to +85℃, ViH-ViL=3.3V
0
500Hz;Ta=25℃;
--
ViH-ViL
3
Ta=25℃
--
Typ.
--
--
--
Max.
24
--
--
1000
--
100%
--
100
--
5
--
7
Unit
VDC
W
Hz
--
nS
V
V
2016.06.22-A/0
Page 1 of 5