English
Language : 

TS107HL-F-2.5 Datasheet, PDF (1/5 Pages) MORNSUN Science& Technology Ltd. – Signal conditioning module
Signal conditioning module
TxxxxHL-F Series
Two-wire Self-Powered signal conditioning module with FEATURES
HART
z Convert voltage to current and offer isolated
power output
z Self-powered, no external supply required
z High accuracy (0.1% F.S.)
z High linearity (0.1% F.S.)
z High isolation voltage(2KVAC/1mA/60s)
z Small size: SIP9 (26*9.5*12.5mm)
z Extremely low temperature drift:50ppm/℃
z Operating temperature range: -40°C ~ +85°C
z High ESD protection(±4KV)
z HART compatible
TxxxxHL-F is a specific with HART smart field instruments launched signal conditioning modules,The isolation module is designed for
transmitting the input voltage signal to the output isolation current that the value is a standard 4~20mA through output loop-powered , the
module can offer a isolation micro-power for the pre-devices. The module also has an integrated HART signal channel,according to the
recommended solutions, it can realize the Half duplex communication of The field and control area,which greatly reduce the wiring cost
between the field and the control area.
The module adopts unique electromagnetic isolation mode and high performance level after. The module achieves the function of
transmitting voltage signal to a 4 ~ 20mA standard signal isolation accurately conversion, which be used in a variety of instruments analog
input port (such as PLC, DCS systems, etc.) to match.
In addition, this module has extremely small form factor (SIP9) and excellent temperature drift characteristics (at -40 ℃ ~ +85 ℃
operating temperature range drift is less than 50PPM / ℃), this module can bear 2KVAC isolation voltage between the input and output.
Selection Guide
Part No.
Loop powered voltage
(VDC)
TS107HL-F-2.5
10~24
TS106HL-F-2.5
10~24
Notes: Customization products are available if required.
Input Signal(VDC)
0.5~2.5
0.5~2.5
Output Signal(mA)
4~20
4~20
Isolation Power
Output (VDC)
3.3
5
Input Specifications
Item
Loop Power supply
Input Power Supply
Max. supply voltage
Input
Input signal
Input impedance
Overload
Operating Conditions
Value
See selection guide
30V(modules work with 30V power supply for
long time , or at no-load condition maybe
damaged by over-heat)
See selection guide
≥10MΩ
≤5V
Output Specifications
Item
Output voltage
Isolation Power
Output voltage accuracy
Max. load current
Operating Conditions
TA=25℃
TA=25℃
Value
See selection guide
Nominal ±3%
≥3mA
Short circuit protection
Continuous, auto-recovery
Output
Output signal
Load capacity
Load regulation
Ripple & noise
24V Power supply, 0~600Ω load
250Ω/0.01μF load
See selection guide
RL≤(Vin–10)/0.02Ω, Vin is supply voltage
≤0.05%F.S./100Ω
Vp-p ≤30mV @ Bandwidth 20MHz
Transmission Specifications
Item
Operating Conditions
Zero Offset
Transmission Error
Value
0.1%F.S.
0.1%F.S.
2014.05.21-A/0
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation