TD102-EX-485 Datasheet, PDF (1/4 Pages) MORNSUN Science& Technology Ltd. – RS485(Full-duplex)input isolation safety barrier
FEATURES
RS485(Full-duplex)input isolation safety l Three-port isolation (input, output and power
barrier
TD102-EX-485(RS485 Full-duplex output)
supply)
l High isolation voltage (2500VAC/60S)
l High reliability (MTBF>500,000 hours)
TD103-EX-485(RS232 output)
GENERAL DESCRIPTION
TD10x-EX-485 input isolation safety barrier, It can supply
isolated DC power of the transmitters from the security zone to the
danger zone, transform the RS-4 85 digital signal of danger zone
into isolated RS-485 or RS-232 digital signal transmission to the
security zone, while increasing the anti-jamming capability of the
industrial production process control system, to ensure system
stability and reliability. It meets IEC/EN61326 standards.
One independent power supply is required. Moreover, within
the product power supply, input and output are mutually isolated.
Field devices connected with this product:
RS-485 bus
ELECTRICAL CHARACTERISTICS
Power Supply
Power
Power Dissipation
18~32VDC(Typ. :24VDC)
About 1.5W
Hazardous
Area
Safe Area
Power Protection
Input signal:RS-485 Full-duplex digital signal
On-site power supply: 5V, 6V:I≤100mA
8V, 9V:I≤50mA
RS-485 Half-duplex digital signal(TD102-EX-485)
RS-232 digital signal(TD103-EX-485)
Reverse protection
SIGNAL CHARACTERISTICS
RS-485
Signal level rules: Standard RS-485 differential level
Transmission delay: ≤10μS
Signal transmission rate: ≤56kbps
RS-232
Signal level rules: Standard RS-232 Logic level
Transmission delay: ≤10μS
Signal transmission rate: ≤56kbps
ISOLATION CHARACTERISTICS
Galvanic Isolation
intrinsically safe end and non-intrinsically safe end 2500VAC 1Min
Isolation Voltage
1.5KVDC between safe area power and signal
1.5KVDC between hazardous area with isolated power output and signal
Test conditions: testing for 1minute, humidity < 70%, leakage current < 5mA
EMC CHARACTERISTICS
EMC
EN61326
OTHER CHARACTERISTICS
Green: Power, lighting at power on.
Signal Indicator
Yellow: Send Indicator, safety side lights when data is sending.
Ambient Temperature
Red: Receive Indicator, safety side lights when data is receiving.
Operation temperature: -25°C ~ +71°C
Transport and storage temperature: -50°C ~ +105°C
Field Devices Connected
and Regions
Equipm ent with RS-485 communication interface
Zone 0, Zone 1, Zone 2, II A, II B, II C, T4~T6 danger zone
Package
35mm DIN-rail package: pluggable connection pin, thickness 22.5mm,Plastic UL94-V0
Safety Class
IP20(IEC60529 / EN60529)
Weight
about 150g
The copyright and authority for the interpretation of the products are reserved by MORNSUN
TD10x-EX-485
2013.07.01-A/1
Page 1 of 4