English
Language : 

MCP100-2A27D27 Datasheet, PDF (1/4 Pages) MORNSUN Science& Technology Ltd. – Industrial grade operating temperature
AC/DC Converter
MCP100 Series
100W, 165~265VAC Input, AC/DC capacitor
charging module power supply
FEATURES
 With charging function, the output ultra-capacitor
RoHS
can be charged
 Industrial grade operating temperature: -40℃ to
75℃
 High isolation voltage: 3000VAC
 Output Voltage continuously adjustable
 Chassis mounting
 MTBF>100,000 H
MCP100---100W converter offered by Mornsun. It features high reliability and high isolation voltage, continuously adjustable output voltage,
They are widely used in power permanent-magnet switch controller, Electricity network cabinet and other electrical equipment. They can
be used as uninterruptible power supply with ultra capacitor.
Selection Guide
Part No.
Output Power
MCP100-2A27D27
100W
Nominal Output Voltage and Current
(Vo1/Io1)
(Voc/Ioc)
27V/1.5A
27V/3A
Efficiency(230VAC, %/Typ.)
85
Max. Capacitive Load(uF)
Vo1
3000
Input Specifications
Item
Input Voltage Rang
Input frequency
Input current
Inrush current
Recommended External Input Fuse
Operating Conditions
AC input
DC input
230VAC
230VAC
Min.
Typ.
Max.
Unit
165
230
265
VAC
200
310
375
VDC
40
50
60
Hz
--
--
1600
mA
--
50
--
A
3.15A, slow fusing
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Vo1
Output Voltage Regulation Range
Voc
24
27
28
VDC
24
27
28
Line Regulation
Load Regulation
Output Current Accuracy*
Output Ripple & Noise**
Charging Capacitor Capacity
Vo1
Vo1
Voc
Vo1 20MHz bandwidth (peak-peak value)
Voc
--
±1
--
--
±3
--
%
--
±3
--
--
100
--
mV
--
--
10
F
Short Circuit Protection
Continuous, self-recovery
Over-voltage Protection
Feedback clamp limiting
Note: *When the voltage on Voc is between 0V and the rated output voltage (24~28V adjustable),the Voc works in constant current mode, and it was constant
voltage mode after the voltage reaches the rated output voltage;
**Ripple and noise tested with “parallel cable” method, please see AC-DC Converter Application Notes for specific operation methods.
General Specifications
Item
Isolation Voltage Input-output
Operating Temperature
Storage Temperature
Storage Humidity
Power Derating
Hot Plug
MTBF
Operating Conditions
Test time: 1min
+55℃~+75℃
Unavailable
MIL-HDBK-217F@25℃ > 100,000 h
Min.
3000
-40
-40
--
3.25
Typ.
Max.
Unit
--
--
VAC
--
+75
℃
--
+105
--
95
%RH
--
--
%/℃
2015.12.15-A/1
Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation