English
Language : 

LS05-15B03SS Datasheet, PDF (1/5 Pages) MORNSUN Science& Technology Ltd. – AC/DC converter
AC/DC Converter
LS05-15BXXSS Series
5W, AC/DC converter
RoHS
FEATURES
z Wide input voltage range: 85~264VAC/100~400VDC
z Over current protection and short circuit protection
z High efficiency, high safety isolation 3000VAC
z Urtal-slim SIP package
z Industrial grade
z Meet IEC60950, UL60950 and EN60950 standards
z UL60950, EN60950 approval
z 3 years of quality assurance
LS05-15BXXSS series is a high efficiency green power modules provided by Mornsun. The features of this series are: Accept either AC or DC
input, wide input voltage, high efficiency, low loss, safety isolation etc. All models are particularly suitable for the applications such as
industrial, electric power, instrumentation, smart home which do not have high requirement on EMC.EMC application circuit must be added
if the products need to be applied to EMC harsh environment .
Selection Guide
Certification
Model
UL/CE
LS05-15B03SS
LS05-15B05SS
LS05-15B09SS
LS05-15B12SS
LS05-15B15SS
LS05-15B24SS
Output Power
3.3W
5W
Nominal Output Voltage
and Current(Vo/Io)
3.3V/1A
5V/1A
9V/0.56A
12V/0.42A
15V/0.34A
24V/0.21A
Efficiency
(230VAC,%/Typ.)
67
74
75
76
77
79
Max. Capacitive Load
(uF)
2200
1500
680
470
330
100
Input Specifications
Item
Input Voltage Range
Input frequency
Input current
Inrush current
leakage Current
Operating Conditions
Conventional
AC input
DC input
115VAC
230VAC
115VAC
230VAC
CY0 is 1nF/400VAC
Min.
Typ.
Max.
Unit
100
--
240
VAC
85
--
264
100
--
400
VDC
47
--
63
Hz
--
--
0.2
--
--
0.1
A
--
5
--
--
10
--
--
--
0.25
mA
Output Specifications
Item
Output Voltage Accuracy
Line Regulation
Load Regulation
Output Ripple & Noise*
Temperature Drift Coefficient
Stand-by Power Consumption
Short Circuit Protection
Over-current Protection
Over-voltage Protection
Min. Load
Operating Conditions
LS05-15B03SS
LS05-15B05/09/12/15/24SS
Full load
10%-100% load
20MHz bandwidth (peak-peak value)
Min.
Typ.
Max.
Unit
--
±2
±3
--
±1
±2
%
--
±0.1
±0.5
--
±1
±1.5
--
50
150
mV
--
±0.02
--
%/°C
--
--
0.5
W
Continuous, self-recovery
≥110%Io self-recovery
Zener clamp diode
0
--
--
%
2014.04.14-A/0
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation