English
Language : 

LH40-10B03_15 Datasheet, PDF (1/7 Pages) MORNSUN Science& Technology Ltd. – 40W, AC/DC converter
AC/DC Converter
LH40 Series
40W, AC/DC converter
FEATURES
z Wide Input voltage range:
85~264VAC/100~370VDC
z Low standby power consumption: 0.5W,
conversion efficiency up to 84%
z Output short circuit, over-current, over-voltage
protection
z Meet IEC61000, UL60950 and EN60950 standards
z Mounting: PCB mounting, Chassis mounting,
DIN-Rail mounting available
RoHS
LH40 series is a 40W efficient environmental-protection AC-DC module power supply, which has advantages such as universal input
voltage, accept either AC or DC input, high efficiency, high reliability, low power consumption and high safety isolation. The series products
are widely used in industries such as industrial control, office.
Note: Please refer to Design Reference when module being used in a bad EMC environment.
Selection Guide
Certification
Part No.*
Output Power
Nominal Output Voltage and Current
(Vo1/Io1)
(Vo2/Io2)
Efficiency
(230VAC, %/Typ.)
Max. Capacitive
Load(μF)
LH40-10B03
26.4W
3.3VDC/8000mA
--
78
60000
LH40-10B05
5VDC/8000mA
--
82
40000
UL/CE
LH40-10B09
LH40-10B12
9VDC/4444mA
--
12VDC/3333mA
--
84
12000
84
9000
LH40-10B15
15VDC/2666mA
--
84
7000
LH40-10B24
24VDC/1667mA
--
84
40W
LH40-10D0512-13
5VDC/5000mA
12VDC/1250mA
82
2000
10000/470
LH40-10D0524-06
5VDC/5000mA
24VDC/625mA
82
10000/400
--
LH40-10A05
+5VDC/4000mA
-5VDC/4000mA
82
±12000
LH40-10A12
+12VDC/1666mA -12VDC/1666mA
84
±4400
LH40-10A15
+15VDC/1333mA -15VDC/1333mA
84
±1000
Note:*product model with a suffix of “A5” means chassis mounting and that with a suffix of “A6” indicates DIN-Rail mounting (e.g. LH40-10B05A5 means chassis
mounting; LH40-10B05A6 means DIN-Rail mounting).
Input Specifications
Item
Input Voltage Range
Input frequency
Input current
Inrush current
Hot Plug
Operating Conditions
AC input
DC input
115VAC
230VAC
115VAC
230VAC
Min.
Typ.
Max.
Unit
85
--
264
VAC
100
--
370
VDC
47
--
440
Hz
--
--
1.0
--
--
0.6
A
--
30
--
--
50
--
Unavailable
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
LH40-10Bxx
Main output
--
±2
--
LH40-10Axx
Main output / Secondary output
--
±2
--
Output Voltage Accuracy
%
Main output
--
±2
--
LH40-10Dxx
Secondary output
--
±5
--
2015.03.02-A/3
Page 1 of 7
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation