PRODUCT FEATURES
1. Universal Input :165~460VAC,50/60Hz
2. AC and DC all in one (input from the same terminal)
3. Low ripple and noise
4. Overload protection and short circuit protection
5. High efficiency, High power density
6. Low loss, green power
7. Industrial level specifications
8. For harsh EMC environment, this series of products must use the
refered application circuit.
SELECTION GUIDE
Model
Package
LH05-16D0512-01
55X45X21.0mm
INPUT SPECIFICATIONS
Input Voltage Range
Input Frequency
Input Current
Recommended
Input Fuse
External
Output Power
3.7W
Output Voltage (Vo1/Io1)
5.0V/0.5A
Output Voltage (Vo2/Io2)
12.0V/0.1A
165~460VAC
47~63Hz
38mA (277VAC )
3.15A/250V
Efficiency (Typ.)
70%
OUTPUT SPECIFICATIONS
Voltage Accuracy Vo1
±2% (main output)
Voltage Accuracy Vo2
±10% (supplement output)
Input variation Vo1
±0.5% (main output)
Input variation Vo2
(balanced load)
±1.5% (supplement output)
Load variation Vo1
±3%(main output)
Load variation Vo2
±5%(supplement output)
Minimum load
10%
Ripple & noise(p-p)
(20MHz Bandwidth)
100mV(max)(main output)
150mV(max)(supplement output)
Short circuit protection
Continuous, and auto resume
Over current protection
≥110%Io
Note :
1.Start
voltage(min)
:150VAC(W hen
the
input
voltage
is
under
150VAC,
model
can
,
t
work).
2.Ripple and Noise were measured by the method of parallel lines;
3. All date in the datasheet are measured according to nominal input voltage, rated output load, TA=25℃, humidity<75%, unless otherwise specified.
COMMON SPECIFICATIONS
Temperature
Specifications
Isolation Voltage
Operating
Temperature
Power derating
Storage Temperature
CVians-eOTuetmperature
Out - Out
EMI
EMC
EMS
MTBF
CE
RE
ESD
EFT
Surge
-40℃~+70℃
2.00%/℃(under -10℃), 3.75%/℃(above 55℃)
-40℃~+105℃
+90℃ (max)
3000VAC/1Min
1000VDC/1Min
CISPR22/EN55022, CLASS A (without external circuit )
CLASS B (with typical applications Figure 3)
CISPR22/EN55022, CLASS A (without external circuit )
CLASS B (with typical applications Figure 3)
IEC/EN 61000-4-2 Contact ±6KV/ Air ±8KV
IEC/EN 61000-4-4 ±4KV(with typical applications Figure 3)
IEC/EN 61000-4-5 ±2KV/±4KV(with typical applications Figure 3)
>300,000h @25℃
perf. Criteria B
perf. Criteria B
perf. Criteria B
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice
LH05-16D0512-01 A/0-2012 Page 1 of 3