English
Language : 

IF0505S-1W Datasheet, PDF (1/4 Pages) MORNSUN Science& Technology Ltd. – 1W, FIXED INPUT, ISOLATED & REGULATED SINGLE OUTPUT DC-DC CONVERTER
FEATURES
l Small Footprint
l SIP/DIP Package
IF_S-1W & IF_D-1W Series
l 3KVDC Isolation
l Temperature Range: -40°C to +85°C
1W, FIXED INPUT, ISOLATED & REGULATED l No Heat sink Required
SINGLE OUTPUT DC-DC CONVERTER
l Internal SMD Construction
l No External Component Required
l Industry Standard Pinout
l RoHS Compliance
Patent Protection RoHS
MODEL SELECTION
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
APPLICATIONS
The IF_S-1W & IF_D-1W Series are specially designed for applications
where a group of polar power supplies are isolated from the input power
supply in a distributed power supply system on a circuit board.
These products apply to:
1) Where the voltage of the input power supply is fixed (voltage variation
≤±5%);
2) Where isolation is necessary between input and output (isolation
voltage ≤3000VDC);
3) Where the regulation of the output voltage and the output ripple noise
are demanded.
PRODUCT PROGRAM
Model
Input Voltage
(VDC)
Nominal
Range
IF0505S-1W
Output Voltage
(VDC)
5
Output Current
(mA)
Max.
Min.
200
20
Input Current
(mA)(Typ.)
@Max. @No
Load
Load
303
Efficiency(%)
@Max. Load
Min.
Typ.
62
66
IF0509S-1W
9
111
12
286
66
70
IF0512S-1W
IF0515S-1W
12
5
4.75-5.25
15
83
9
278
68
72
30
67
7
274
69
73
IF0505D-1W
5
200
20
303
62
66
IF0512D-1W
12
83
9
278
68
72
IF1205S-1W
5
200
20
124
63
67
IF1212S-1W
IF1215S -1W
12
12
11.4-12.6
15
83
9
114
69
73
15
67
7
113
70
74
IF1205D-1W
5
200
20
124
63
67
IF2405S-1W
5
200
20
62
63
67
IF2412S-1W
IF2415S-1W
12
24
22.8-25.2
15
83
9
57
69
73
8
67
7
56
70
74
IF2405D-1W
5
200
20
62
63
67
Note: The IF_S(D)-W25 Series also available in our company.
OUTPUT SPECIFICATIONS
Item
Line regulation
Load regulation
Test condition
For Vin change of ±5%
10% to 100% load
Min.
Typ.
--
--
--
±1
Output voltage accuracy
100% load
--
--
Temperature drift
100% load
--
--
Output ripple*
20MHz Bandwidth
--
10
Output Noise*
20MHz Bandwidth
--
50
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at DC-DC Application Notes.
Max.
±0.25
±2
±3
0.03
20
100
Unit
%
%/℃
mVp-p
COMMON SPECIFICATION
Item
Test Conditions
Storage humidity range
Non condensing
Min.
Typ.
--
--
Max.
Unit
95
%
The copyright and authority for the interpretation of the products are reserved by MORNSUN
IF_S-1W & IF_D-1W 2013.11.21-A/4 Page 1 of 4