English
Language : 

H0505D-1W Datasheet, PDF (1/2 Pages) MORNSUN Science& Technology Ltd. – DUAL/SINGLE OUTPUT DC-DC CONVERTER
G_D-1W & H_D-1W Series
1W, FIXED INPUT, 6000V ISOLATED & UNREGULATED
DUAL/SINGLE OUTPUT DC-DC CONVERTER
FEATURES
Small Footprint
DIP Package
6KVDC Isolation
Temperature Range: -40°C to+85°C
No Heat Sink Require
No External Component Require
Internal SMD Construction
Industry Standard Pinout
RoHS Compliance
APPLICATIONS
The G_D-1W & H_D-1W Series are specially
designed for applications where a group of polar
power supplies are isolated from the input power
supply in a distributed power supply system on a
circuit board.
These products apply to:
1) Where the voltage of the input power
supply is fixed (voltage variation ≤±10%);
2) Where isolation is necessary between
input and output (isolation voltage ≤6000VDC);
3) Where the regulation of the output voltage
and the output ripple noise are not demanded.
Such as: purely digital circuits, ordinary low
frequency analog circuits, and IGBT power
device driving circuits.
PRODUCT PROGRAM
multi-country patent protection RoHS
Part
Num ber
Input
Voltage (VDC)
Nominal Range
Volt age
(VDC)
Output
Current (mA)
Max
Min
Efficiency
(%, Typ)
Cert ific at e
H0505D-1W
5
200
20
70
UL
H0509D-1W
9
111
12
72
UL
H0512D-1W
12
84
9
73
UL
H0515D-1W *
15
67
7
74
UL
5
4.5-5.5
G0505D-1W
±5
±100
±10
70
UL
G0509D-1W
±9
±56
±6
71
UL
G0512D-1W
±12
±42
±5
72
UL
G0515D-1W *
±15
±33
±4
73
UL
H1205D-1W
5
200
20
70
UL
H1209D-1W
9
111
12
71
UL
H1212D-1W
12
84
9
72
UL
H1215D-1W
15
67
7
74
UL
12 10.8-13.2
G1205D-1W
±5
±100
±10
70
UL
G1209D-1W
G1212D-1W
±9
±56
±6
71
UL
±12
±42
±5
72
UL
G1215D-1W
±15
±33
±4
75
UL
* Designing.
ISOLATION SPECIFICATIONS
Item
Test Conditions
Min Typ Max Units
Isolation voltage
Tested for 1 minute and 1mA max 6000
VDC
Isolation resistance
Test at 1000VDC
1000
MΩ
Isolation capacitance
3.5
pF
MODEL SELECTION
H0505D-1W
Rated Power
Package Style
Outpu t Voltage
Input Voltage
Product Series
MORNSUN Science & Technology co.,Ltd.
Address:2th floor 6th building, Hangzhou Industrial
District, Guangzhou, China
Tel: 86-20-38601850
Fax: 86-20-38601272
http://www.mornsun-power.com
COMMON SPECIFICATIONS
Item
Test Conditions
Min Typ Max Units
Storage humidity range
Operating temperature
Storage temperature
Temp. rise at full load
Lead temperature
Short circuit protection*
Cooling
Case material
MTBF
Weight
1.5mm from case for 10 seconds
5V input voltage
12V input voltage
95
%
-40
85
-55
125
°C
15 30
300
1
s
Continuous
Free air convection
Plastic(UL94-V0)
3500
K hours
8.2
g
* When input voltage (Nominal) is 5V, Supply voltage must be discontinued at the end of short circuit
duration.
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
G_D-1W & H_D-1W A/3-2009 Page 1 of 2