English
Language : 

F0505XT-W2R2 Datasheet, PDF (1/4 Pages) MORNSUN Science& Technology Ltd. – Continuous short-circuit protection
DC/DC Converter
F_XT-W2R2 Series
0.25W, Fixed input voltage, isolated & unregulated
single output
FEATURES
 Continuous short-circuit protection
 Operating temperature range: -40℃ to +105℃
 High efficiency up to 77%
 Miniature SMD package
 Isolation voltage: 3K VDC
 International standard pin-out
Patent Protection RoHS
F_XT-W2R2 series are specially designed for applications where an isolated voltage is required in a distributed power supply system. They are
suitable for
1. Where the voltage of the input power supply is stable (voltage variation: ±10%Vin);
2. Where isolation between input and output is necessary (isolation voltage ≤3000VDC);
3. Where the output voltage regulation is not strictly required;
4. Typical application: preceding-stage interference isolation condition; ground-interference canceled condition; digit circuit condition;
Voltage-isolation converting condition; normal low-frequency artificial circuit condition; relay drive circuit condition, etc.
Selection Guide
Input Voltage (VDC)
Part No.
Nominal
(Range)
F0505XT-W2R2
F1205XT- W2R2
5
(4.5-5.5)
12
(10.8-13.2)
Output
Output Voltage
(VDC)
Output Current
(mA)(Max./Min.)
Efficiency (%,Min./Typ.) Max. Capacitive Load
@ Full Load
(µF)
5
50/5
72/77
220
5
50/5
72/77
Input Specifications
Item
Input Current
(full load / no-load)
Reflected Ripple Current
Surge Voltage (1sec. max.)
Input Filter
Hot Plug
Operating Conditions
5V input
12V input
5V input
12V input
5V input
12V input
Min.
Typ.
Max.
--
68/15
--
--
27/10
--
--
20
--
--
5
--
-0.7
--
9
-0.7
--
18
Filter capacitor
Unavailable
Unit
mA
VDC
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Output Voltage Accuracy
See tolerance envelope curve(Fig. 1)
Line Regulation
Input voltage change: ±1%
--
--
±1.2
--
Load Regulation
10%-100% load
--
12
15
%
Ripple & Noise*
20MHz bandwidth
--
20
50
mVp-p
Temperature Coefficient
Full load
--
--
±0.03
%/℃
Short Circuit Protection
Continuous, self-recovery
Note: * Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application Notes for specific operation.
General Specifications
Item
Operating Conditions
Min.
Typ.
Isolation Voltage
Input-output, with the test time of 1 minute and the leak
current lower than 1mA
3000
--
Isolation Resistance
Input-output, isolation voltage 500VDC
1000
--
Max.
--
--
Unit
VDC
MΩ
2015.09.25-A/0
Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation