English
Language : 

F0505RN-1W Datasheet, PDF (1/3 Pages) MORNSUN Science& Technology Ltd. – SINGLE OUTPUT, DC-DC CONVERTER
F_RN-1W & F_RT-1W Series
1W, FIXED INPUT,3000V ISOLATED & UNREGULATED
SINGLE OUTPUT, DC-DC CONVERTER
RoHS
FEATURES
● Small Footprint, Ultra-thin package
● 3KVDC Isolation
● Temperature Range: -40°C ~ +85°C
● No Heatsink Required
● High Power Density
● No External Component Required
● Industry Standard Pinout
● Compatible with DCP01 Series
● Short Circuit Protection
● RoHS Compliance
PRODUCT PROGRAM
Part
Number
Input
Voltage (VDC)
Nominal Range
F0505RN-1W
5
F0505RT-1W
4.5-5.5
Voltage
(VDC)
5
Output
Current (mA)
Max.
Min.
200
20
Efficiency Package
(%, Typ.) Style
DIP
74
SMD
APPLICATIONS
The F_RN-1W & F_RT-1W series are specially
designed for applications where a group of polar
power supplies are isolated from the input power
supply in a distributed power supply system on a
circuit board.
These products apply to:
1) Where the voltage of the input power supply
is fixed (voltage variation ≤ ±10%);
2) Where isolation is necessary between input
and output (isolation voltage ≤3000VDC);
3) Where the regulation of the output voltage
and the output ripple noise are not
demanding.
Such as: purely digital circuits, ordinary low
frequency analog circuits, and IGBT power
device driving circuits.
MODEL SELECTION
F0505RN-1W
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development
center, Science Ave., Guangzhou Science City,
Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
Http://www.mornsun-power.com
COMMON SPECIFICATIONS
Item
Test Conditions
Storage humidity
Operating temperature
Storage temperature
Temp. rise at full load
Lead temperature
1.5mm from case for 10 seconds
Short circuit protection
Cooling
Package material
MTBF
Weight
Min. Typ. Max. Units
95
%
-40
85
-55
125
°C
15 25
250
Continuous, auto-recovery
Free air convection
Epoxy Resin (UL94-V0)
3500
k hours
1.4
g
OUTPUT SPECIFICATIONS
Item
Test Conditions
Min. Typ. Max. Units
Output power
Line regulation
Load regulation
For Vin change of 1%
10% to 100% load
0.1
1
W
±1.2
%
12.8 15
Output voltage accuracy
Temperature drift
Nominal input,100% full load
See tolerance envelope graph
±0.03 %/°C
Ripple &Noise*
20MHz bandwidth 50% load
Nominal input
100% load
20
mVp-p
50 75
Switching frequency Full load, nominal input
100
kHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.