English
Language : 

F0303XT-1W Datasheet, PDF (1/3 Pages) MORNSUN Science& Technology Ltd. – DC/DC Converter
DC/DC Converter
F_XT-1W Series
1W, Fixed input voltage, isolated & unregulated single FEATURES
output
l Efficiency up to 79%
l Isolation voltage: 3K VDC
l Operating temperature range: -40℃ to +85℃
l SMD package
l Internal surface mounted design
Patent Protection RoHS
l International standard pin-out
F_XT-1W series is specially designed for applications where an isolated voltage is required in a distributed power supply system. It is suitable
for
1.Where the voltage of the input power supply is stable (voltage variation: ±10%Vin);
2.Where isolation is necessary between input and output (isolation voltage ≤3000VDC);
3.Where do not has high requirement of line regulation , load regulation and the ripple & noise of the output voltage;
Such as: pure digital circuits, low frequency analog circuits, and IGBT power device driving circuits.
Selection Guide
Input Voltage (VDC)
Part No.
Nominal
(Range)
F0303XT-1W
F0305XT-1W
3.3
(2.97-3.63)
F0505XT-1W
F0512XT-1W
F0515XT-1W
F1205XT-1W
5
(4.5-5.5)
12
(10.8-13.2)
Output
Output Voltage
(VDC)
3.3
5
5
12
15
Output Current
(mA)(Max./Min.)
303/31
200/20
200/20
83/9
67/7
5
200/20
Input Specifications
Item
Operating Conditions
Min.
3.3V input
--
Input Current (full load / no-load) 5V input
--
12V input
--
3.3V input
-0.7
Surge Voltage (1sec. max.)
5V input
-0.7
12V input
-0.7
Input Filter
Efficiency
(%,Min./Typ.)
@ Full Load
69/73
70/74
73/77
75/79
74/78
65/69
Max. Capacitive
Load
(µF)
220
Typ.
Max.
415/40
--
278/25
--
121/15
--
--
5
--
9
--
18
Capacitor filter
Unit
mA
VDC
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Output Voltage Accuracy
See tolerance envelope graph (Fig. 1)
Line Regulation
Input voltage change: ±1%
--
--
±1.2
--
3.3VDC output
--
15
20
Load Regulation
10%-100% load
5VDC output
12VDC output
--
12.5
15
%
--
6.8
10
15VDC output
--
6.3
10
Ripple & Noise*
20MHz bandwidth
--
75
100
mVp-p
Temperature Drift Coefficient
100% load
--
--
±0.03
%/℃
Output Short Circuit Protection**
--
--
1
s
Note: 1. * Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
2. ** Supply voltage must be discontinued at the end of short circuit duration.
2014.05.22-A/2
Page 1 of 3
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation