GbX® Backplane and Daughtercard Tooling
*GbX® is a Trademark of Amphenol Corp.
5.1 GbX® Backplane Repair Procedure:
For the removal and replacement of Signal Pair pins.
The following tools are required:
Signal Pair Pin Replacement Tool 62202-2090
Shield Removal Tool
62202-2100
5/16” T-handle wrench *
Needle nose pliers (miniature) *
Tweezers *
Plastic hammer *
* Not supplied by Molex
NEEDLE NOSE
PLIERS
CONNECTOR
Removal
To remove damaged signal pins, grasp them with the needle
SIGNAL PINS
nose pliers and pull straight up from the board. It is
recommended that both pins in a pair be replaced. See Figure
FIGURE 5-1
5-1. In some cases it may be necessary to straighten a bent pin with the tweezers to allow access with the pliers.
NOTE: Never reuse a backplane signal pin once it has been removed. Also, no more than three pins should be
pressed into any plated through hole.
Replacement
To replace pairs of pins, use insertion tool no. 62202-2090.
Note: The pins are left and right handed and must be loaded into the connector in their proper orientation. They
should be positioned in the insertion tool so that the
ribs on the center of the pins are located in the
grooves in the tip of the tool, facing the round
indentations. Due to the small size of the pins, a
INSERTION
TOOL
62202-2090
tweezers may help in this operation. There should be
a slight friction fit when the pins are inserted all the
way in to the tip. See Figure 5-2. Carefully load and
push the pins down into the connector base until the
tool stops against the board. See Figure 5-3. Then
remove the inserter from the connector.
CONNECTOR
INSERTION
TOOL
62202-2090
RIB OF PIN
IN THE GROOVE
OF TOOL
SIGNAL PINS
ROUND
INDENTATIONS
Figure 5-2
SIGNAL PINS
Figure 5-3
Doc. No: TM-622022099
Revision: H
Release Date: 06-23-04
Revision Date: 01-28-11
UNCONTROLLED COPY