MM1075 Datasheet, PDF (3/10 Pages) Mitsumi Electronics, Corp. – System Reset (with built-in watchdog timer) Monolithic IC
MITSUMI
System Reset (with built-in watchdog timer) MM1075
Electrical Characteristics (AC) (Except where noted otherwise, Ta=25°C, VCC=5V)
Item
VCC input pulse width
CK input pulse width
CK input cycle
Watchdog timer
* monitoring time 2
Reset time for
* watchdog timer 3
Reset hold time for
* power supply rise 4
Output delay time
from VCC
*5
Output rise time
*6
Output fall time
*6
Measurement
Symbol circuit
Measurement conditions
5V
TP1
2
VCC
4V
TCKW
2
CK
or
TCK
2
TWD
2
CT=0.1µF
RCT=OPEN
TWR
2
CT=0.1µF
TPR
TPD1
TPD2
tR1
tR2
tF1
tF2
2
CT=0.1µF, VCC
RESET pin
2
RL1=2.2kΩ, CL1=100pF
RESET pin
2
R1, 2=10kΩ, CL2=20pF
RESET pin
2
RL1=2.2kΩ, CL1=100pF
RESET pin
2
RL2=10kΩ, CL2=20pF
RESET pin
2
RL1=2.2kΩ, CL1=100pF
RESET pin
2
RL2=10kΩ, CL2=20pF
Min. Typ. Max. Units
8
µS
3
µS
20
µS
50 100 150 mS
1 2 3 mS
50 100 150 mS
2 10
µS
3 10
1.0 1.5 µS
1.0 1.5 µS
0.1 0.5 µS
0.5 1.0 µS
Notes:
*1 ICT1 changes according to RCT pin (Pin 6) pull up resistance.
*2 Monitoring time is the time from the last pulse (negative edge) of the timer clear clock pulse until reset
pulse output. In other words, reset output is output if a clock pulse is not input during this time. Also,
monitoring time can be varied by pulling up the RCT pin to VCC with a resistor (RCT). Monitoring time
adjustments are shown in Graph 1.
*3 Reset time means reset pulse width. However, this does not apply to power ON reset.
*4 Reset hold time is the time from when VCC exceeds detection voltage (VSH) during power ON reset until
--------------------------------------------------------------
reset release (RESET output high, RESET output low).
*5 Output delay time is the time from when power supply voltage drops below detection voltage (VSI) until
--------------------------------------------------------------
reset (RESET output low, RESET output high).
*6 Voltage range when measuring output rise and fall is 10~90%.
*7 Watchdog timer monitoring time (TWD), watchdog timer reset time (TWR) and reset hold time (TPR) during
power supply rise can be changed by varying CT capacitance. The times are expressed by the following
formulae. The recommended range for CT is 0.001~10µF.
TPR (mS) - ~ 1000 CT (µF)
TWD (mS) - ~ 1000 CT (µF)
TWR (mS) - ~ 20 CT (µF)
Example : When CT=0.1µF (RCT pin OPEN)
TPR - ~ 100mS
TWD - ~ 100mS
TWR - ~ 2mS