BUS CONTROLLED 3CH VIDEO PRE-AMP FOR CRT DISPLAY MONITOR
2
I C BUS CONTROL SECTION
SDA,SCL CHARACTERISTICS
parameter
symbol
MIN
MAX
unit
min. input LOW voltage.
VIL
-0.5
1.5
V
max. input HIGH voltage.
VIH
3.0
5.5
V
SCL clock frequency.
fSCL
0
100
KHz
Time the bus must be free before a new transmission can start.
tBUF
4.7
-
us
Hold time start condition.After this period the first clock pulse
is generated.
tHD:STA
4.0
-
us
The LOW period of the clock.
The HIGH period of the clock.
Srt up time for start condition. (Only relevant for a repeated
start condition.)
Hold time DATA.
Set-up time DATA.
Rise time of both SDA and SCL lines.
Fall time of both SDA and SCL lines.
Set-up time for stop condition.
tLOW
4.7
-
us
tHIGH
4.0
-
us
tSU:STA
4.7
-
us
tHD:DAT
0
-
us
tSU:DAT
250
-
ns
tR
-
1000
ns
tF
-
tSU:STO
4.0
300
ns
-
us
tR, tF
tBUF
VIL
SDA
VIH
VIL
SCL
VIH
tHD:STA
S
tSU:DAT
tHD:DAT
tLOW
tHIGH
tSU:STA
S
tSU:ST
O
P
S
MITSUBISHI
5
25