PM100CLB060 Datasheet, PDF (4/6 Pages) Mitsubishi Electric Semiconductor – FLAT-BASE TYPE INSULATED PACKAGE | |||
|
◁ |
MITSUBISHI <INTELLIGENT POWER MODULES>
PM100CLB060
FLAT-BASE TYPE
INSULATED PACKAGE
CONTROL PART
Symbol
Parameter
Condition
Limits
Min.
Typ.
Max. Unit
ID
Circuit Current
VD = 15V, VCIN = 15V
VN1-VNC
â
VXP1-VXPC
â
15
25
mA
5
10
Vth(ON) Input ON Threshold Voltage Applied between : UP-VUPC, VP-VVPC, WP-VWPC
Vth(OFF) Input OFF Threshold Voltage
UN ⢠VN ⢠WN-VNC
1.2
1.5
1.8
V
1.7
2.0
2.3
SC
Short Circuit Trip Level
â20⤠Tj ⤠125°C, VD = 15V
(Fig. 3,6)
200
â
â
A
toff(SC)
Short Circuit Current Delay
Time
VD = 15V
(Fig. 3,6) â
0.2
â
µs
OT
VD = 15V
Over Temperature Protection
OTr
Detect Tj of IGBT chip
Trip level
Reset level
135
145
â
°C
â
125
â
UV
Supply Circuit Under-Voltage â20 ⤠Tj ⤠125°C
UVr
Protection
Trip level
Reset level
11.5
12.0 12.5
V
â
12.5
â
IFO(H)
IFO(L)
Fault Output Current
VD = 15V, VFO = 15V
(Note-3)
â
â
â
0.01
mA
10
15
Minimum Fault Output Pulse
tFO
Width
VD = 15V
(Note-3)
1.0
1.8
â
ms
(Note-3) Fault output is given only when the internal SC, OT & UV protections schemes of either upper or lower arm device operate to
protect it.
MECHANICAL RATINGS AND CHARACTERISTICS
Symbol
â
â
Parameter
Mounting torque
Weight
Mounting part
Condition
â
Limits
Min.
Typ.
Unit
Max.
screw : M5
2.5
3.0
3.5 N ⢠m
â
340
â
g
RECOMMENDED CONDITIONS FOR USE
Symbol
Parameter
VCC
Supply Voltage
VD
Control Supply Voltage
VCIN(ON) Input ON Voltage
VCIN(OFF) Input OFF Voltage
Condition
Recommended value
Unit
Applied across P-N terminals
⤠400
V
Applied between : VUP1-VUPC, VVP1-VVPC
VWP1-VWPC, VN1-VNC
(Note-4)
15 ± 1.5
V
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN ⢠VN ⢠WN-VNC
⤠0.8
V
⥠9.0
fPWM
PWM Input Frequency
Using Application Circuit of Fig. 8
⤠20
kHz
tdead
Arm Shoot-through
Blocking Time
For IPMâs each input signals
(Fig. 7)
⥠2.0
µs
(Note-4) With ripple satisfying the following conditions dv/dt swing ⤠±5V/µs, Variation ⤠2V peak to peak
Apr. 2004
|
▷ |