English
Language : 

PS22A78-E Datasheet, PDF (3/11 Pages) Mitsubishi Electric Semiconductor – Dual-In-Line Package Intelligent Power Module
< Dual-In-Line Package Intelligent Power Module >
PS22A78-E
TRANSFER MOLDING TYPE
INSULATED TYPE
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise noted)
INVERTER PART
Symbol
Parameter
Condition
VCE(sat)
VEC
ton
tC(on)
toff
tC(off)
trr
ICES
Collector-emitter saturation
voltage
FWDi forward voltage
VD=VDB = 15V, VIN= 5V, IC= 35A
VIN= 0V, -IC= 35A
Tj= 25°C
Tj= 125°C
Switching times
VCC= 600V, VD= VDB= 15V
IC= 35A, Tj= 125°C, VIN= 0↔5V
Inductive Load (upper-lower arm)
Collector-emitter cut-off
current
VCE=VCES
Tj= 25°C
Tj= 125°C
Limits
Unit
Min. Typ. Max.
-
1.90 2.60
V
-
2.00 2.70
-
2.20 2.80 V
0.50 1.20 1.90 μs
-
0.60 0.90 μs
-
2.40 3.50 μs
-
0.60 0.90 μs
-
0.50
-
μs
-
-
1
mA
-
-
10
CONTROL (PROTECTION) PART
Symbol
Parameter
Condition
Limits
Unit
Min. Typ. Max.
ID
Circuit current
IDB
ISC
UVDBt
UVDBr
UVDt
UVDr
Short circuit trip level
P-side Control supply
under-voltage
protection(UV)
N-side Control supply
under-voltage
protection(UV)
Total of VP1-VPC, VN1-VNC
VD=15V, VIN=0V
VD=15V, VIN=5V
Each part of VUFB-VUFS,
VVFB-VVFS, VWFB-VWFS
VD=VDB=15V, VIN=0V
VD=VDB=15V, VIN=5V
-20°C≤Tj≤125°C, Rs= 48.7Ω (±1%),
Not connecting outer shunt resistors to
NU,NV,NW terminals
Tj ≤125°C
Trip level
Reset level
Tj ≤125°C
Trip level
Reset level
-
-
5.60
-
-
5.60
mA
-
-
1.10
-
-
1.10
(Note 3) 59.5
-
-
A
10.0
-
12.0 V
10.5
-
12.5 V
10.3
-
12.5 V
10.8
-
13.0 V
VFOH
VFOL
Fault output voltage
VSC = 0V, FO terminal pulled up to 5V by 10kΩ
VSC = 1V, IFO = 1mA
4.9
-
-
V
-
-
0.95
V
tFO
Fault output pulse width
CFO=22nF
(Note 4) 1.6
2.4
-
ms
IIN
Input current
VIN = 5V
0.70 1.00 1.50 mA
Vth(on)
Vth(off)
ON threshold voltage
OFF threshold voltage
Applied between UP, VP, WP, UN, VN, WN-VNC
-
-
3.5
V
0.8
-
-
VOT
Temperature output
LVIC temperature = 85°C
(Note 5) 3.57 3.63 3.69 V
Note 3: Short circuit protection detects sense current divided from main current at N-side IGBT and works for N-side IGBT only. In the case that outer shunt resistor is
inserted into main current path, protection current level ISC changes. For details, please refer the application note for this DIPIPM.
Note 4: Fault signal is output when short circuit or N-side control supply under-voltage protection works. The fault output pulse-width tFO depends on the capacitance of
CFO. (CFO (typ.) = tFO x (9.1 x 10-6) [F])
Note 5: DIPIPM doesn't shut down IGBTs and output fault signal automatically when temperature rises excessively. When temperature exceeds the protective level that
user defined, controller (MCU) should stop the DIPIPM immediately. This output might exceed 5V when temperature rises excessively, so it is recommended to
insert a clamp Di between controller supply (e.g. 5V) and VOT output for overvoltage protection. Temperature of LVIC vs. VOT output characteristics is described in
Fig.2
Publication Date : January 2012
3