English
Language : 

PM150CVA120_09 Datasheet, PDF (3/6 Pages) Mitsubishi Electric Semiconductor – FLAT-BASE TYPE INSULATED PACKAGE
MITSUBISHI <INTELLIGENT POWER MODULES>
PM150CVA120
FLAT-BASE TYPE
INSULATED PACKAGE
TOTAL SYSTEM
Symbol
Parameter
Condition
Supply Voltage Protected by VD = 13.5 ~ 16.5V, Inverter Part,
VCC(PROT) SC
Tj = 125°C Start
VCC(surge) Supply Voltage (Surge)
Applied between : P-N, Surge value or without
switching
Module Case Operating
TC
Temperature
(Note-1)
Tstg
Storage Temperature
Viso
Isolation Voltage
60Hz, Sinusoidal, Charged part to Base, AC 1 min.
(Note-1) TC measurement point is below. (3mm depth at the center of the side of base plate)
Ratings
800
1000
–20 ~ +100
–40 ~ +125
2500
Unit
V
V
°C
°C
Vrms
Tc
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise noted)
INVERTER PART
Symbol
Parameter
VCE(sat)
VEC
ton
trr
tc(on)
toff
tc(off)
ICES
Collector-Emitter
Saturation Voltage
FWDi Forward Voltage
Switching Time
Collector-Emitter
Cutoff Current
Test Condition
VD = 15V, IC = 150A
VCIN = 0V
–IC = 150A, VD = 15V, VCIN = 15V
Tj = 25°C
Tj = 125°C
VD = 15V, VCIN = 0V↔15V
VCC = 600V, IC = 150A
Tj = 125°C
Inductive Load (upper and lower arm)
VCE = VCES, VCIN = 15V
Tj = 25°C
Tj = 125°C
Limits
Unit
Min.
Typ.
Max.
—
2.65 3.30
—
2.75 3.35
V
—
2.50 3.50
V
0.4
0.9
2.3
—
0.2
0.3
—
0.4
1.0
µs
—
2.4
3.4
—
0.7
1.2
—
—
—
—
1
10
mA
CONTROL PART
Symbol
Parameter
Test Condition
Limits
Min.
Typ.
Max. Unit
ID
Circuit Current
VD = 15V, VCIN = 15V
VN1-VNC
V*P1-V*PC
—
72
100
mA
—
24
34
Vth(ON) Input ON Threshold Voltage Applied between : UP-VUPC, VP-VVPC, WP-VWPC
Vth(OFF) Input OFF Threshold Voltage
UN • VN • WN-VNC
1.2
1.5
1.8
V
1.7
2.0
2.3
SC
Short Circuit Trip Level
–20≤ Tj ≤ 125°C, VD = 15V
200
—
—
A
toff(SC)
Short Circuit Current Delay
Time
VD = 15V
—
10
—
µs
OT
Base-plate
Trip level
OTr
Over Temperature Protection Temperature detection, VD = 15V
Reset level
111
118
125
°C
—
100
—
UV
Supply Circuit Under-Voltage
UVr
Protection
–20 ≤ Tj ≤ 125°C
Trip level
Reset level
11.5
12.0 12.5
V
—
12.5
—
IFO(H)
IFO(L)
Fault Output Current
VD = 15V, VFO = 15V
—
(Note-2)
—
—
0.01
mA
10
15
Minimum Fault Output Pulse
tFO
Width
VD = 15V
(Note-2) 1.0
1.8
—
ms
(Note-2) Fault output is given only when the internal SC, OT & UV protection.
Fault output of OT protection operate by lower arm
Fault output of OT, UV protection given pulse while over level.
Jun. 2005