TIMING REQUIREMENTS (VCC = 5 V ± 10%, VSS = 0 V, Ta = –20 to +85 °C, f(XIN) = 25 MHz, unless otherwise noted (Note 1))
Notes 1. This applies when the main clock division selection bit = “0” and f(f2) = 12.5 MHZ.
2. Input signal’s rise/fall time must be 100 ns or less, unless otherwise noted.
External clock input
Symbol
tc
tw(H)
tw(L)
tr
tf
Parameter
External clock input cycle time (Note 1)
External clock input high-level pulse width (Note 2)
External clock input low-level pulse width (Note 2)
External clock rise time
External clock fall time
Limits
Unit
Min.
Max.
40
ns
15
ns
15
ns
8
ns
8
ns
Notes 1. When the main clock division selection bit = “1”, the minimum value of tc = 80 ns.
2. When the main clock division selection bit = “1”, values of tw(H) / tc and tw(L) / tc must be set to values from 0.45 through 0.55.
Microprocessor mode
Symbol
tsu(P4D–RDE)
tsu(P5D–RDE)
tsu(P6D–RDE)
tsu(P7D–RDE)
tsu(P8D–RDE)
th(RDE–P4D)
th(RDE–P5D)
th(RDE–P6D)
th(RDE–P7D)
th(RDE–P8D)
Port P4 input setup time
Port P5 input setup time
Port P6 input setup time
Port P7 input setup time
Port P8 input setup time
Port P4 input hold time
Port P5 input hold time
Port P6 input hold time
Port P7 input hold time
Port P8 input hold time
Parameter
Limits
Min.
Max.
Unit
60
ns
60
ns
60
ns
60
ns
60
ns
0
ns
0
ns
0
ns
0
ns
0
ns
Microprocessor mode
Symbol
tsu(D–RDE) Data input setup time
___
tsu(RDY– 1) RDY input setup time
____
tsu(HOLD– 1) HOLD input setup time
th(RDE–D)
th( 1–RDY)
th( 1–HOLD)
Data input hold time
___
RDY input hold time
____
HOLD input hold time
Parameter
Limits
Unit
Min.
Max.
32
ns
55
ns
55
ns
0
ns
0
ns
0
ns
20