English
Language : 

MF1037S-1 Datasheet, PDF (1/1 Pages) Mitsubishi Electric Semiconductor – FOR PERSONAL HANDYPHONE SYSTEM
MF1037S-1
FOR PERSONAL HANDYPHONE SYSTEM
DESCRIPTION
This SAW filter for the RF circuit of personal
handyphone system.
FEATURES
1. SMD package insures small size, lightweight.
2. Adjustment free.
3. Low insertion loss and high stop band
attenuation.
4. Wide and sharp passband characteristics.
5. High stability and reliability.
6. Designed for reflow solderings.
APPLICATION
• Portable telephone
• Wireless equipment
MAXIMUM RATINGS
Rating
Value
Unit
Input Power
40
mW
Operating Temperature Range –20 to 75
°C
Storage Temperature Range –30 to 85
°C
ELECTRICAL PERFORMANCE
Parameter
PASSBAND FREQUENCY
PASSBAND CHARACTERISTICS
Insertion Loss
Ripple
VSWR
STOPBAND ATTENUATION
1395 – 1418 MHz
1645 – 1668 MHz
MF1037S-1
Min Typ Max Units
1895 – 1918 MHz
2.3 3.0 dB
0.3 1.5 dBp-p
1.7 2.5
30 42
dB
30 42
dB
PACKAGE OUTLINE DIMENSIONS
3.6
GND
1.8
GND 1.25
IN
GND
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,GONDUT ,,,,,,,,,,,,,
BOTTOM VIEW
SIDE VIEW
3.8
OUT
IN
TOP VIEW
Unit : mm
DIMENSIONS ARE IN MILLIMETERS
±0.2 UNLESS OTHERWISE SPECIFIED
– 32 –
MF1037S-1
MF1037S-1 TYPICAL CHARACTERISTICS
Insertion Loss vs. Frequency
CH1 S21 log MAG
[dB] 0
1 dB / REF 0 dB
–1
–2
–3
–4
–5
Input VSWR vs. Frequency
CH1 S11 SWR
500 m / REF 1
3.0
2.0
CH1 CENTER 1 906.500 000 MHz
SPAN 100.000 000 MHz
Attenuation vs. Frequency
CH2 S 21 log MAG
[dB] 0
5 dB / REF 0 dB
1.0
CH1 CENTER 1 906.500 000 MHz
SPAN 100.000 000 MHz
Output VSWR vs. Frequency
CH1 S22 SWR
500 m / REF 1
–10
–20
–30
3.0
2.0
START 1 906.500 000 MHz
STOP 1 500.000 000 MHz
Input Reflection Coefficient vs. Frequency
CH1 S11 1 U FS
1.0
CH1 CENTER 1 906.500 000 MHz
SPAN 100.000 000 MHz
Output Reflection Coefficient vs. Frequency
CH1 S22 1 U FS
MARKER 1 : 1906.5 MHz
MARKER 2 : 1895 MHz
MARKER 3 : 1918 MHz
CH1 CENTER 1 906.500 000 MHz
SPAN 100.000 000 MHz
Attenuation vs. Frequency
CH1 S21 log MAG
[dB] 0
5 dB / REF 0 dB
–10
–20
–30
–40
CH1 CENTER 1 906.500 000 MHz
MARKER 1 : 1906.5 MHz
MARKER 2 : 1895 MHz
MARKER 3 : 1918 MHz
SPAN 100.000 000 MHz
×2
START .300 000 MHz
STOP 3 000.000 000 MHz
– 33 –