English
Language : 

M54133FP Datasheet, PDF (1/12 Pages) Mitsubishi Electric Semiconductor – EARTH LEAKAGE CURRENT DETECTOR
MITSUBISHI <CONTROL / DRIVER IC>
M54133FP/GP
EARTH LEAKAGE CURRENT DETECTOR
DESCRIPTION
The M54133 is a semiconductor integrated circuit designed for
high-speed type earth leakage breakers. This IC has built-in anti-
lightning-surge function and anti-inverter-noise function.
FEATURES
q Improvement of ability against unwanted tripping by lightning
-surge.
•Adopt the two times counting system.
•Improvement of ability against needless action for lightning-
impulse.
q Improvement of ability against unwanted tripping by inverter
-noise.
•Built-in operational amplifier (of low current dissipation) for active
low-pass filter.
•Improvement of ability against needless action for high
frequency and high harmonics.
q Built-in delay time function
•An external capacitor is used to set the delay time.
q High input sensitivity : VT=11.5mVrms Typ.
q Low-current dissipation (at RIREF=180kΩ)
•In stand-by condition : IS=610µA Typ.
q High stabilities design
•Adopt the circuits that is not affected by fluctuations of supply
voltage/ambient temperature.
APPLICATION
Earth leakage breaker
RECOMMENDED OPERATING CONDITIONS
Supply voltage range............................................................7 to 12V
Operating ambient temperature.....................................-20 to +85°C
BLOCK DIAGRAM
PIN CONFIGURATION (TOP VIEW)
GND 1
IREF 2
VCC 3
OFFC 4
TRC1 5
TRC2 6
DLYC 7
SCRT 8
16 VS
15 OPI+
14 C1
13 OPI-
12 C2
11 OPAO
10 ILKI
9 VREF
Outline 16P2N-A(FP)
Outline 16P2E-A(GP)
VS
OPI+
C1
OPI-
C2
OPAO
ILKI
VREF
16
15
14
13
12
11
10
9
M54133FP/GP
POWER SUPPLY CIRCUIT
–
A
+
LEAKAGE DETECTION
SCR
DRIVER
1
GND
2
IREF
3
4
5
6
7
8
VCC
OFFC
TRC1
TRC2
DLYC
SCRT