M54125L Datasheet, PDF (1/6 Pages) Mitsubishi Electric Semiconductor – EARTH LEAKAGE CURRENT DETECTOR | |||
|
MITSUBISHI <CONTROL / DRIVER IC>
M54125L/P
EARTH LEAKAGE CURRENT DETECTOR
DESCRIPTION
The M54125 is a semiconductor integrated circuit consisting of an
amplifier for high-speed earth leakage circuit breaker.
FEATURES
q Satisfies JIS C 8371
q Temperature-stable input current trigger threshold (VLKT = 9mV)
q Capable of detecting a lost phase on the neutral line
q Economical, low external component count
q Highly resistant to noise and power surges
q Wide operating temperature range (Ta = -20 â +80°C)
APPLICATION
High-speed earth-leakage circuit breakers
FUNCTION
The M54125 is a semiconductor integrated circuit for use in the
amplifier section of earth-leakage circuit breakers. It consists of a
differential amplifier, one-shot circuit, output circuit, current
regulator, waveform regulator and delay circuit. The following
description refers to the block diagram, application example, and
operational waveforms.
PIN CONFIGURATION (TOP VIEW)
Capacitor MM ââ 1
Output OUT â 2
GND 3
NC 4
Capacitor CTD TD ââ 5
NC 6
Capacitor CWF WF ââ 7
Input IBL â 8
External resistor RX â 9
NC 10
NC 11
VS 12
Input ILK â 13
Bias voltage VB 14
Outline 14P5A
N.C: no connection
Input ILK â 1
Bias voltage VB 2
Capacitor MM ââ 3
Output OUT â 4
GND 5
10 VS
9 â RX External resistor
8 â IBL Input
7 ââ WF Capacitor CWF
6 ââ TD Capacitor CTD
Outline 10P2-C
BLOCK DIAGRAM (Note: Pin No. in parentheses are of M54125L)
VS
10
(12)
External
resistor
RX
9
(9)
Input
IBL
8
(8)
Capacitor CWF
WF
7
(7)
Capacitor CWF
TD
6
(5)
Voltage
regulator
Bias
current
source
Comparator
VBLT
Wave-
form
regulator
VCC
VB
A ⢠VLKT
A
Amplifier
Comparator
One-shot
multi vibrator
(13) (14)
1
2
ILK VB
Input Bias
M54125L/P
(1)
3
MM
Capacitor
Delay
circuit
Output
circuit
(2)
4
OUT
Output
(3)
5
GND
|
▷ |