English
Language : 

LK1AF Datasheet, PDF (1/3 Pages) Mitsubishi Electric Semiconductor – SLIM POWER RELAY WITH HIGH INRUSH CURRENT CAPABILITY
VDE
LK-RELAYS SLIM POWER RELAY WITH
HIGH INRUSH CURRENT
CAPABILITY
11.0
24.0
.433
.945
25.0
.984
mm inch
FEATURES
1. High inrush current capability
1) Operating load capability:
inrush 100 A, steady 5 A
2) UL/CSA, TV-5
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
2) Surge withstand voltage between con-
tact and coil: 10,000 V or more
3. High noise immunity realized by the
card separation structure between
contact and coil
4. Popular terminal pitch in AV equip-
ment field
mm inch
COM
Coil
N.O.
16.5
.650
20
.787
1
.039
7.5
.295
1
.039
Creepage distance and clear-
ances in compliance with IEC65
Card
Partition wall
5. Space-saving slim type
Base area: Width 11 × Length 24 mm
Width .433 × Length .945 inch
6. Conforms to the various safety stan-
dards
UL, CSA, VDE, TÜV, SEMKO, SEV, BSI
approved
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive
load)
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Expected Mechanical (at 180 cpm)
life (min. Electrical (at 20 cpm)
ope.)
(at rated load)
1 Form A
Max. 100 mΩ
Silver alloy
5 A 277 V AC, 5 A 30 V DC
1,385 VA, 150 W
277 V AC, 30 V DC
5A (AC), 5 A (DC)
2 × 106
105
Coil
Nominal operating power
530 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 Detection current: 10mA
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time.
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*6 Half-wave pulse of sine wave: 6 ms
*7 Detection time: 10 µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Characteristics
Max. operating speed
20 cpm
Initial insulation resistance*1
Min. 1,000 MΩ (at 500 V DC)
Initial
Between open contacts
breakdown
voltage*2 Between contacts and coil
1,000 Vrms for 1 min
4,000 Vrms for 1 min
Initial surge voltage between con-
tact and coil*3
Min. 10,000 V
Operate time*4 (at nominal voltage) Approx. 7 ms (at 20°C 68°F)
Release time (without diode)*4
(at nominal voltage)
Approx. 2 ms (at 20°C 68°F)
Temperature rise (at 70°C)
Max. 35°C with nominal coil voltage
at 5A contact carrying current
(resistance method)
Shock
Functional* 5
resistance Destructive*6
Min. 200 m/s2
Min. 1,000 m/s2
Vibration
resistance
Functional* 7
Destructive
10 to 55 Hz
at double amplitude of 1.5 mm
10 to 55 Hz
at double amplitude of 1.5 mm
Conditions for operation, Ambient temp.
transport and storage*8 Humidity
(Not freezing and condens-
ing at low temperature) Air pressure
–40 to +70°C -40 to +158°F
5 to 85%R.H.
86 to 106 kPa
Unit weight
Approx. 12 g .42 oz
TYPICAL APPLICATIONS
• AV equipment: TV’s, VTR’s, etc.
• OA equipment
• HA equipment
ORDERING INFORMATION
Ex.
LK
1a
F
—
Contact arrangement
Protective construction
1a: 1 Form A
F: Flux-resistant type
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard.
(Note) Standard packing Carton: 100 pcs. Case: 500 pcs.
24V
Coil voltage (DC)
5, 9, 12, 24 V
59