MT91600 Datasheet, PDF (9/16 Pages) Mitel Networks Corporation – Programmable SLIC | |||
|
◁ |
Preliminary Information
MT91600
Component List* for a Typical Application with a Resistive 600⦠Line Impendance - Refer to
Figure 5 for component designation and recommended conï¬guration
Resistor Values
R1
220⦠1% (0.15% matched), 1W
R2
220⦠1% (0.15% matched), 1W
R3
43kâ¦
R4
130kâ¦
R5
220â¦
R6
75kâ¦
R7
3kâ¦
R8
1kâ¦
R9
1kâ¦
R10
560kâ¦
R11
55kâ¦
R12
112kâ¦
R13
100kâ¦
R14
100kâ¦
R15
100kâ¦
R16
138kâ¦
R17
100kâ¦
R18
75kâ¦
R19
0â¦
R20
2kâ¦
R21
2kâ¦
R22
1kâ¦
R23
248â¦
Capacitor Values
C1
100nF, 5%
C2
300nF, 5%
C3
100pF, 5%
C4
33nF, 20%
C5
3.3nF, 5%
C6
1uF, 20%, 16V
C7
100nF, 20%
C8
0F
C9
100nF, 20%
C10
100nF, 5%
C11
47pF, 20%
C12
33nF, 10%
C13
100nF 20%
Diodes and Transistors
D1
BAS16 or equivalent
D2a/b
BAV99 dual diode or equivalent
D3a/b
BAV99 dual diode or equivalent
Q1
2N2222 or MPSA42 or MMBTA42
Q2
2N2907 or MPSA92 or MMBTA92
Q3
2N2222 or MPSA42 or MMBTA42
Q4
2N2907 or MPSA92 or MMBTA92
Note: All resistors are 1/4 W, 1% unless otherwise indicated.
*Assumes Zo = ZNB = 600â¦, Gain 2 - 4 = -1dB, Gain 4 - 2 = -1dB.
Decoupling capacitors, (1uF, 100V, 20%), can be added to VDD, VEE, VBAT and VRLY to provide improved
PSRR performance.
K1
= Electro-mechanical relay, 5V, DPDT/2 FORM C
PR1 = This device must always be ï¬tted to ensure damage does not occur from inductive loads.For
simple applications, PR1 can be replaced by a single TVS, such as 1.5KE220C, across tip and ring. For
applications requiring lightning and mains cross protection further circuitry will be required and the following
protection devices are suggested: P2353AA, P2353AB (Teccor), THBT20011, THBT20012, THBT200S (SGS-
Thomson), TISP2290, TSSP8290L (T.I.)
9
|
▷ |