English
Language : 

MBU100 Datasheet, PDF (3/6 Pages) Total Power International – MBU100 SERIES 1WATT ULTRA MINIATURE HIGH SIP DC/DC CONVERTERS
MBU100 Series
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Load
Temperature Coefficient
Output Short Circuit
Conditions
For Vin Change of 1%
Io=20% to 100%
Over Line, Load & Temp.
Min.
Typ.
Max.
---
{1.0
{3.0
---
{1.2
{1.5
See Model Selection Guide
---
100
150
---
---
200
---
---
5
120
---
---
---
{0.01
{0.02
0.5 Second Max.
Unit
%
%
%
mV P-P
mV P-P
mV rms
%
%/]
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
Conditions
60 Seconds
Flash Tested for 1 Second
500VDC
100KHz,1V
MIL-HDBK-217F @ 25], Ground Benign
Min.
1000
1100
1000
---
50
2000
Typ.
---
---
---
60
90
---
Max.
---
---
---
100
110
---
Unit
VDC
VDC
M[
pF
KHz
K Hours
Capacitive Load
Models by Vout
5V
Maximum Capacitive Load
33
9V
12V
15V
Unit
33
33
33
uF
Input Fuse Selection Guide
5V Input Models
500mA Slow - Blow Type
12V Input Models
200mA Slow - Blow Type
24V Input Models
100mA Slow - Blow Type
3
MINMAX
REV:0 2005/04