English
Language : 

AKF-15 Datasheet, PDF (3/6 Pages) Minmax Technology Co., Ltd. – 15 Watts Universal Input Range AC/DC Power Modules
AKF-15 Series
Input Specifications
Parameter
Input Voltage Range
Input Frequency Range
Inrush Current (Cold Start at 25])
Conditions
All Models
115VAC
230VAC
Min.
Typ.
Max.
Unit
85
---
265
VAC
47
---
440
Hz
---
---
15
A
---
---
30
A
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Cross Regulation-
Dual Positives / Triple Output
Ripple & Noise (20MHz)
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
Conditions
Min. Typ. Max.
Unit
--- {1.0 {2.0
%
Vin=Min. to Max.
--- {0.5 {1.0
%
Single Output
Iout=Min. to Max.
Dual / Triple Output
--- {0.5 {1.0
%
--- {2.5 {5.0
%
Vo1
--- {1.0 ---
%
Vo2
Measured output Io = 20% to 100% of rated load
Other output are set at 50% of rated load
---
{2.5
---
%
Vo3
--- {2.5 ---
%
5.0VDC Output
---
1.5
1.8 %Vpp of Vo
Other Output
---
0.8
1.0 %Vpp of Vo
Zener diode clamp
---
120
---
% of Vo
--- {0.01 {0.02
%/]
--- ---
5.0
%
85VAC, Hiccup technique, auto-recovery
105
---
---
%
Hiccup mode, indefinite (automatic recovery)
General Specifications
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
Switching Frequency
Hold-up Time
MTBF
Conditions
Input to Output, 60 Seconds
Input to Output, Flash Tested for 1 Second
500VDC
115VAC, 60Hz
MIL-HDBK-217F @ 25], Ground Benign
Min.
Typ.
Max.
Unit
3000
---
---
VAC
4700
---
---
VDC
100
---
---
M[
---
100
---
KHz
---
20
---
ms
280
---
---
K Hours
Input Fuse
Built-in Fuse
External Fuse (Recommended)
All Models
2A / 250VAC
1.5A Slow - Blow Type
3
MINMAX