English
Language : 

S2E00 Datasheet, PDF (2/6 Pages) Minmax Technology Co., Ltd. – 1.5W, Ultra-High Isolation DIP, Single & Dual Output DC/DC Converters
S2E00 Series
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
S2E01
S2E02
S2E03
S2E04
S2E05
S2E06
S2E07
S2E08
S2E09
S2E10
S2E11
S2E12
S2E13
S2E14
S2E15
S2E16
S2E17
S2E18
VDC
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
15
(13.5 ~ 16.5)
VDC
5
12
15
{5
{12
{15
5
12
15
{5
{12
{15
5
12
15
{5
{12
{15
Output Current
Max.
Min.
mA
mA
300
125
100
0
{150
{63
{50
300
125
100
0
{150
{63
{50
300
125
100
0
{150
{63
{50
Input Current
@Max. Load
mA (Typ.)
400
400
400
400
400
400
167
167
167
167
167
167
133
133
133
133
133
133
@No Load
mA (Typ.)
50
30
30
Reflected
Ripple
Current
mA (Typ.)
30
25
20
Efficiency
@Max. Load
% (Typ.)
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
Absolute Maximum Ratings
Parameter
Input Surge Voltage
( 1000 mS )
5VDC Input Models
12VDC Input Models
15VDC Input Models
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
Min.
-0.7
-0.7
-0.7
---
---
Max.
7
17
21
260
1,000
Unit
VDC
VDC
VDC
]
mW
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conditions
Min. Max. Unit
Ambient
-40 +85
]
Case
-40 +95
]
-55 +125 ]
--- 95
%
Free-Air Convection
Notes :
1. Specifications typical at Ta=+25], resistive load,
nominal input voltage, rated output current unless
otherwise noted.
2. Ripple & Noise measurement bandwidth is 0-20
MHz.
3. All DC/DC converters should be externally fused at
the front end for protection.
4. Operation under no-load conditions will not
damage these modules; however, they may not
meet all specifications listed.
5. Other input and output voltage may be available,
please contact factory.
6. Specifications subject to change without notice.
REV:0 2005/04
MINMAX
2