English
Language : 

MSAU100_11 Datasheet, PDF (2/4 Pages) Minmax Technology Co., Ltd. – DC/DC CONVERTER 1W, SMD Package with Industry Standard Pinout
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Temperature Coefficient
Short Circuit Protection
General Specifications
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
Moisture Sensitivity Level (MSL)
Input Fuse
5V Input Models
500mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Power Derating Curve
100
80
60
40
Natural
convection
100LFM
200LFM
400LFM
Conditions
For Vin Change of 1%
Io=20% to 100%
Over Line, Load & Temp.
MSAU100 SERIES
DC/DC CONVERTER 1W, SMD-Package
Min.
Typ.
Max.
Unit
---
±1.0
±3.0
%
---
±1.2
±1.5
%
See Model Selection Guide
---
60
120
mV P-P
---
---
150
mV P-P
---
---
15
mV rms
---
±0.01
±0.02
%/℃
0.5 Second Max.
Conditions
60 Seconds
500 VDC
100KHz, 1V
MIL-HDBK-217F@25℃, Ground Benign
IPC/JEDEC J-STD-020D
12V Input Models
200mA Slow-Blow Type
Min.
1000
1000
---
50
2,000,000
Typ.
Max.
---
---
---
---
40
100
100
140
---
---
Level 3
Unit
VDC
MΩ
pF
KHz
Hours
24V Input Models
100mA Slow-Blow Type
Conditions
Ambient
Min.
Max.
-40
+85
---
+90
-50
+125
---
95
Free-Air convection
---
260
Unit
℃
℃
℃
% rel. H
℃
100
Natural
80
convection
100LFM
60
200LFM
400LFM
40
20
20
0
~
-40
0
20
40
60
80
Ambient Temperature ]
(5V & 12Vin)
100 110
0
~
-40
0
20
40
60
80
Ambient Temperature ]
(24Vin)
100 110
Notes
1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2 Ripple & Noise measurement bandwidth is 0-20MHz.
3 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
however they may not meet all specifications listed.
4 All DC/DC converters should be externally fused at the front end for protection.
5 Other input and output voltage may be available, please contact factory.
6 Specifications subject to change without notice.
E-mail:sales@minmax.com.tw Tel:886-6-2923150