English
Language : 

MRWI60C_15 Datasheet, PDF (2/6 Pages) Minmax Technology Co., Ltd. – DC/DC Power Module 60W
MRWI60C SERIES
DC/DC Power Module 60W
Remote On/Off Control
Parameter
Converter On
Converter Off
Control Input Current (On)
Control Input Current (Off)
Control Common
Standby Input Current
Output Specifications
Parameter
Output Voltage Setting Accuracy
Line Regulation
Load Regulation
Minimum Load
Ripple & Noise
Transient Recovery Time
Transient Response Deviation
Over Voltage Protection
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Conditions
Min.
Typ.
Max.
Unit
3.5V ~ 12V or Open Circuit
0V ~ 1.2V or Short Circuit
Vctrl = 5.0V
---
---
0.5
mA
Vctrl = 0V
---
---
-0.5
mA
Referenced to Negative Input
Supply Off & Nominal Vin
---
3
---
mA
Conditions/Model
Min.
Typ.
---
±1.0
Vin=Min. to Max. @Full Load
---
±0.2
Io=0% to 100%
---
±0.5
No minimum Load Requirement
5.1V Output Models
---
---
0-20MHz bandwith 12V & 24V Output Models
---
---
48V Output Models
---
---
25% Load Step Change(2)
---
250
---
±3
Zener diode clamp
---
120
---
±0.02
Hiccup
---
150
Hiccup Mode 0.25 Hz typ., Automatic Recovery
Max.
Unit
±2.0
%Vnom.
±1.5
%
±1.0
%
100
mV P-P
150
mV P-P
200
mV P-P
---
μsec
±5
%
---
% of Vo
---
%/℃
---
%
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
Safety Approvals
Conditions
Min.
Typ.
Max.
60 Seconds
2500
---
---
500 VDC
1000
---
---
100KHz, 1V
---
---
3000
---
210
---
MIL-HDBK-217F@25℃, Ground Benign
242,029
UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1 (CB-report)
Unit
VDC
MΩ
pF
KHz
Hours
Environmental Specifications
Parameter
Operating Ambient Temperature Range
Natural Convection (5)
Nominal Vin, 100% Load
(for Power Derating see relative Derating Curves)
Thermal Impedance
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Conditions/Model
Min.
MRWI60-48S12C
MRWI60-24S12C, 24S24C, 24S48C
-40
MRWI60-48S051C, 48S24C, 48S48C
MRWI60-24S051C
Natural Convection
3.5
100LFM Convection
1.95
200LFM Convection
1.61
400LFM Convection
1.33
---
-50
---
Natural Convection
Max.
Unit
76
74
℃
71
---
℃/W
---
℃/W
---
℃/W
---
℃/W
+95
℃
+125
℃
95
% rel. H
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2015/08/31 REV:3 Page 2 of 6