English
Language : 

MJWI20 Datasheet, PDF (2/9 Pages) Minmax Technology Co., Ltd. – DC/DC CONVERTER 20W, Highest Power Density
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
Output Specifications
Parameter
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Load Cross Regulation (Dual Output)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Over Voltage Protection
Conditions
Min.
Typ.
At 50% Load and Nominal Vin
---
---
Dual Output, Balanced Loads
---
---
Vin=Min. to Max.
Single Output
Dual Output
---
---
---
---
Min. Load to Full Load Single Output
3.3V & 5V
12V,15V & 24V
---
---
---
---
Dual Output
---
---
Asymmetrical Load 25%/100% Full Load
---
---
3.3V & 5V Models
---
75
12V & 15V Models
---
100
24V Models
---
150
Dual Output Models
---
100
25% Load Step Change
---
300
---
---
Current Limitation at 150% typ. of Iout max., Hiccup
Hiccup Automatic Recovery
For Shutdown Voltage see Model Selection Guide
Max.
±1.0
±2.0
±0.2
±0.5
±0.5
±0.2
±1.0
±5.0
---
---
---
---
---
±0.02
Unit
%Vnom.
%
%
%
%
%
%
%
mV P-P
mV P-P
mV P-P
mV P-P
μsec
%/℃
General Specifications
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF(calculated)
Safety Approvals
Conditions
Min.
Typ.
Max.
60 Seconds
1500
---
---
500 VDC
1000
---
---
100KHz, 1V
---
---
1500
---
330
---
MIL-HDBK-217F@25℃, Ground Benign
346,000
---
---
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Unit
VDC
MΩ
pF
KHz
Hours
Input Fuse
24V Input Models
5000mA Slow-Blow Type
48V Input Models
2500mA Slow-Blow Type
Remote On/Off Control
Parameter
Converter On
Converter Off
Control Input Current (on)
Control Input Current (off)
Control Common
Standby Input Current
Conditions
Min.
Typ.
Max.
Unit
3.5V ~ 12V or Open Circuit
0V ~ 1.2V or Short Circuit
Vctrl = 5.0V
---
---
0.5
mA
Vctrl = 0V
---
---
-0.5
mA
Referenced to Negative Input
Supply Off & Nominal Vin
---
10
---
mA
Output Voltage Trim
Parameter
Trim Up / Down Range
Conditions
% of nominal output voltage
Min.
Typ.
Max.
Unit
±10
---
---
%
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2012/07/16 REV:12 Page 2 of 9