English
Language : 

MAU300 Datasheet, PDF (2/6 Pages) Total Power International – MAU300 Series 2 Watt Ultra Miniature High Isolation SIP DC/DC Single & Dual Output
MAU300 Series
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
MAU301
MAU302
MAU303
MAU304
MAU305
MAU306
MAU307
MAU311
MAU312
MAU313
MAU314
MAU315
MAU316
MAU317
MAU321
MAU322
MAU323
MAU324
MAU325
MAU326
MAU327
VDC
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
24
(21.6 ~ 26.4)
VDC
3.3
5
12
15
{5
{12
{15
3.3
5
12
15
{5
{12
{15
3.3
5
12
15
{5
{12
{15
Output Current
Max.
mA
500
400
165
133
{200
{83
{66
500
400
165
133
{200
{83
{66
500
400
165
133
{200
{83
{66
Min.
mA
10
8
3
2.5
{4
{1.5
{1
10
8
3
2.5
{4
{1.5
{1
10
8
3
2.5
{4
{1.5
{1
Input Current
Load
Efficiency
Regulation
@Max. Load
mA (Typ.)
452
526
495
499
519
504
501
185
212
200
200
210
201
200
92
108
101
101
105
102
100
@No Load
mA (Typ.)
60
30
15
% (Max.)
11
11
7
7
10
7
7
8
8
5
5
8
5
5
8
8
5
5
8
5
5
@Max. Load
% (Typ.)
73
76
80
80
77
79
79
74
78
82
83
79
82
82
74
77
81
82
79
81
82
Absolute Maximum Ratings
Parameter
Input Surge Voltage
( 1000 mS )
5VDC Input Models
12VDC Input Models
24VDC Input Models
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
Min.
-0.7
-0.7
-0.7
---
---
Max.
9
18
30
260
650
Unit
VDC
VDC
VDC
]
mW
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conditions
Min. Max. Unit
Ambient
-40 +85
]
Case
-40 +90
]
-40 +125 ]
--- 95
%
Free-Air Convection
Notes :
1. Specifications typical at Ta=+25], resistive load,
nominal input voltage, rated output current unless
otherwise noted.
2. Ripple & Noise measurement bandwidth is 0-20
MHz.
3. These power converters require a minimum output
loading to maintain specified regulation.
4. Operation under no-load conditions will not
damage these modules; however, they may not
meet all specifications listed.
5. All DC/DC converters should be externally fused at
the front end for protection.
6. Other input and output voltage may be available,
please contact factory.
7. Specifications subject to change without notice.
REV:0 2005/04
MINMAX
2