English
Language : 

MA01_16 Datasheet, PDF (2/4 Pages) Minmax Technology Co., Ltd. – DC/DC CONVERTER 1W, SIP-Package
Output Specifications
Parameter
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise
Temperature Coefficient
Short Circuit Protection
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
Safety Approvals
MA01 SERIES
DC/DC CONVERTER 1W, SIP-Package
Conditions
Min.
Typ.
Max.
Dual Output, Balanced Loads
---
±0.1
±1.0
For Vin Change of 1%
---
±1.05
±1.2
Io=20% to 100%
See Model Selection Guide
0-20MHz Bandwidth
---
30
60
---
±0.01
±0.02
0.5 Second Max., Automatic Recovery
Unit
%
%
mV P-P
%/℃
Conditions
Min.
Typ.
Max.
60 Seconds
1000
---
---
1 Second
1200
---
---
500 VDC
1000
---
---
100KHz, 1V
40
60
120
50
100
120
MIL-HDBK-217F@25℃, Ground Benign
2,000,000
UL/cUL 60950-1 recognition (CSA certificate), IEC/EN 60950-1(CB-report)
Unit
VDC
VDC
MΩ
pF
KHz
Hours
Environmental Specifications
Parameter
Operating Ambient Temperature Range (See
Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Natural Convection
Min.
-40
---
-50
---
Natural Convection
---
Max.
Unit
+85
℃
+95
℃
+125
℃
95
% rel. H
260
℃
Power Derating Curve
100
80
60
Natural
Convection
20 LFM
400LFM
40
20
0
-40
~
50
60
70
80
90
Ambient Temperature C
100
110
Output Voltage Tolerance
+20%
+15%
+10%
+5%
Vnom
-5%
Max.
Typ.
Min.
-10%
0%
20%
40%
60%
80%
Output Load Current (%)
+20%
+15%
+10%
+5%
Vnom
-5%
-10%
100%
Notes
1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
3 We recommend to protect the converter by a slow blow fuse in the input supply line.
4 Other input and output voltage may be available, please contact factory.
5 That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
6 Specifications are subject to change without notice.
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2015/07/31 REV:6 Page 2 of 4