English
Language : 

AZF-60_16 Datasheet, PDF (2/4 Pages) Minmax Technology Co., Ltd. – AC/DC Power Module 60W
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise
Minimum Load
Over Voltage Protection
Transient Response Deviation
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
AZF-60 SERIES
AC/DC POWER MODULE 60W
Conditions
Min.
---
Vin=Min. to Max. @Full Load
---
Io=10% to 100%
---
0-20 MHz Bandwidth
5.1VDC Output Models
Other Output Models
---
---
---
Zener diode clamp
---
(Iout=100% to Iout=50%)
---
---
Foldback, auto-recovery
(long term overload condition may cause damage)
105
Hiccup mode, Automatic Recovery
Typ.
±1.0
±0.2
±0.5
2.0
1.0
10
120
±3
±0.02
---
---
Max.
Unit
±2.0
%
±1.0
%
±1.0
%
3.0
%VPP of Vo
1.3
%VPP of Vo
---
%Inom.
---
% of Vo
±6
%
---
%/℃
5
% Vout
---
%Inom.
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
Protection Class II
Safety Approvals
Conditions
Min.
Typ.
Max.
Input to Output, 60 Seconds
3000
---
---
500 VDC
100
---
---
---
100
---
---
20
---
MIL-HDBK-217F@25℃, Ground Benign
125,000
According IEC/EN 60536
UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1 (CB-report)
UL/cUL 508 listed certificate
Unit
VACrms
MΩ
KHz
ms
Hours
Environmental Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
Operating Ambient Temperature Range
Natural Convection
-10
---
+70
℃
Storage Temperature Range
-40
---
+85
℃
Power Derating
+50℃ to +70℃
2.25
W/℃
Power Derating (5.1Vout)
Thermal Shutdown
+40℃ to +70℃
2.25
W/℃
Shutdown, Internal IC Junction Temperature
---
142
---
℃
Automatic Recovery, Internal IC Junction Temperature
---
67
---
℃
Humidity (non condensing)
---
---
95
% rel. H
Cooling
Natural Convection
Lead Temperature (1.5mm from case for 10Sec.)
---
---
260
℃
EMC Specifications
Parameter
EMI
EMS
Standards & Level
Conduction and Radiation EN55011, EN55022, FCC part 15
EN55011 ,EN55024
ESD
EN61000-4-2 Air ± 8kV , Contact ± 4kV
Radiated immunity
EN61000-4-3 10V/m
Fast transient
EN61000-4-4 ±2kV
Surge
EN61000-4-5 ±1kV
Conducted immunity
EN61000-4-6 10Vrms
PFMF
EN61000-4-8 30A/m
Dips
EN61000-4-11 30% 10ms
Interruptions
EN61000-4-11 >95% 5000ms
Performance
Class B
B
A
B
B
B
A
B
C
Notes
1 All specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless otherwise noted.
2 These power modules require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage the power
supplies however they may not meet all listed specifications.
3 Other input and output voltage may be available, please contact factory.
4 That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
5 Specifications are subject to change without notice
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2016/08/30 REV:14 Page 2 of 4