English
Language : 

AZF-60_13 Datasheet, PDF (2/4 Pages) Minmax Technology Co., Ltd. – AC/DC Power Module 60W Fully encapsulated Plastic Case
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Minimum Load
Over Voltage Protection
Transient Response Deviation
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
AZF-60 SERIES
AC/DC POWER MODULE 60W
Conditions
Min.
Typ.
---
±1.0
Vin=Min. to Max.
---
±0.2
Iout=Min. to Max.
---
±0.5
5.1VDC Output Models
---
2.0
Other Output Models
---
1.0
---
10
Zener diode clamp
---
120
(Iout=100% to Iout=50%)
±3
---
±0.02
---
---
Foldback, auto-recovery
(long term overload condition may cause damage)
105
---
Hiccup mode, indefinite (automatic recovery)
Max.
Unit
±2.0
%
±1.0
%
±1.0
%
3.0
%VPP of Vo
1.3
%VPP of Vo
---
%Inom.
---
% of Vo
±6
%
---
%/℃
5
% Vout
---
%Inom.
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
EMC Emission
EMC Immunity according
EN61000-6-1
Protection Class II
Safety Approvals
Conditions
Input to Output, 60 Seconds
500 VDC
MIL-HDBK-217F@25℃, Ground Benign
Conducted and radiated
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Min.
Typ.
Max.
Unit
3000
---
---
VACrms
100
---
---
MΩ
---
100
---
KHz
---
20
---
ms
125,000
---
---
Hours
EN 55011 class B, EN 55022 class B, FCC part 15 class B
Specification Requirement
Performance Criteria
Air ±8KV Cont. ±4KV
B
80~1000MHz, 10V/m 80% AM, 1KHz modulation
A
AC port ±2KV DC, SL, TL ±2KV not less than 1 min.
B
1.2/50µS(8/20µS) AC dif. ±1KV DC ±0.5KV
B
0.15~80MHz, 10Vrms (functional earth ports included)
80% AM, 1KHz modulation
B
50Hz/60Hz, 30A/m
A
30%, 10ms
B
60%, 100ms, 95%, 5000ms
C
According IEC/EN 60536
cUL/UL 60950-1,IEC/EN 60950-1
(UL508 for models with order code suffix ICE only)
Input Fuse
Built-in Fuse
External Fuse (Recommended)
All Models
6A / 250VAC
3A Slow – Blow Type
Environmental Specifications
Parameter
Temperature Range (operational)
Power Derating
Power Derating (5.1Vout)
Storage Temperature Range
Over Temperature Protection
Cooling
Humidity (non condensing)
Ambient
+50℃ to +70℃
+40℃ to +70℃
Conditions
-10℃
-40℃
at 90℃ (automatic recovery at 67℃)
Free-Air convection
---
+70℃
2.25W / ℃
2.25W / ℃
+85℃
95 % rel. H
Notes
1 All specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless otherwise noted.
2 Ripple & Noise measurement bandwidth is 0~20 MHz
3 These power modules require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage the power
supplies however they may not meet all listed specifications.
4 Other input and output voltage may be available, please contact factory.
5 Long term short circuit operation may cause damage to the unit.
6 Specifications are subject to change without notice
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2013/02/25 REV:11 Page 2 of 4