English
Language : 

AQF-30_12 Datasheet, PDF (2/5 Pages) Minmax Technology Co., Ltd. – AC/DC Power Module 30W Fully encapsulated Plastic Case
Input Specifications
Parameter
Input Voltage Range
Input Frequency Range
Input Voltage Range
Inrush Current (Cold Start at 25℃)
Model
All Models
115VAC
230VAC
AQF-30 SERIES
AC/DC POWER MODULE 30W
Min.
Typ.
Max.
Unit
85
---
264
VAC
47
---
440
Hz
120
---
370
VDC
---
---
20
A
---
---
40
A
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Cross Regulation-
Dual / Triple Output Models
Ripple & Noise (20MHz)
Minimum Load
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
Conditions
Min.
Typ.
Single / Dual Output
---
±1.0
Dual Positive / Triple Output
Vo1
---
±1.0
Vo2&Vo3
---
±3.0
Vin=Min. to Max.
---
±0.2
Single Output Models
---
±0.5
Iout=Min. to Max.
Dual Output Models
Triple Output Models
Vo1
Vo2&Vo3
---
---
---
±2.5
±2.5
±4.0
Vo1
Vo2
Vo3
Measured output Io = 20% to 100% of rated load
Other output(s) set at 50% of rated load
---
±2.0
---
±5.0
---
±5.0
3.3V & 5VDC Output Models
---
1.5
Other Output Models
---
1.0
Single-,Dual-Output Models and Main Output Triple Output Models ---
10
Auxiliary Outputs of Triple Output Models
---
20
Zener diode clamp
---
120
---
±0.02
---
---
Foldback, auto-recovery
(long term overload condition may cause damage)
105
---
Hiccup mode, indefinite (automatic recovery)
Max.
Unit
±2.0
%
±2.0
%
---
%
±1.0
%
±1.0
%
±5.0
%
±5.0
%
---
%
---
%
---
%
---
%
1.8
%VPP of Vo
1.3
%VPP of Vo
---
%Inom.
---
%Inom.
---
% of Vo
---
%/℃
5
% Vout
---
% Inom.
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
EMC Emission
EMC Immunity according
EN61000-6-1
Protection Class II
Safety Approvals
Conditions
Input to Output, 60 Seconds
500 VDC
MIL-HDBK-217F@25℃, Ground Benign
Conducted and radiated
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Min.
Typ.
Max.
Unit
3000
---
---
VACrms
100
---
---
MΩ
---
100
---
KHz
---
20
---
ms
200,000
---
---
Hours
EN 55011 class B, EN 55022 class B, FCC part 15 class B
Specification Requirement
Performance Criteria
Air ±8KV Cont. ±4KV
B
80~1000MHz, 10V/m 80% AM, 1KHz modulation
A
AC port ±2KV DC, SL, TL ±2KV not less than 1 min.
B
1.2/50uS(8/20μS) AC dif. ±1KV DC ±0.5KV
B
0.15~80MHz, 10Vrms (functional earth ports included)
80% AM, 1KHz modulation
B
50Hz/60Hz, 30A/m
A
30%, 10ms
B
60%, 100ms, 95%, 5000ms
C
According IEC/EN 60536
cUL/UL 60950-1,IEC/EN 60950-1
(UL508 for models with order code suffix ICE only)
Input Fuse
Built-in Fuse
External Fuse (Recommended)
All Models
3.5A / 250VAC
1.5A Slow – Blow Type
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2012/11/14 REV:19 Page 2 of 5