Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise
Minimum Load
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
AAF-05 SERIES
AC/DC POWER MODULE 5W
Conditions
Min.
Typ.
---
---
Vin=Min. to Max. @Full Load
---
---
Io=0% to 100%
---
---
3.3V & 5VDC Output Models
---
---
0-20 MHz Bandwidth
Other Output Models
---
---
No minimum Load Requirement
Zener Diode Clamp
---
125
---
---
---
---
Foldback, auto-recovery
135
150
(long term overload condition may cause damage)
Hiccup mode, Automatic Recovery
Max.
Unit
±2.0 %Vnom.
±1.0
%
±1.0
%
60
mVPP of Vo
1
%VPP of Vo
190
±0.05
5
---
% of Vo
%/℃
%Vout
%Inom.
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
Protection Class II
Safety Approvals
EMC Specifications
Parameter
EMI
EMS
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(See Power Derating Curve)
Storage Temperature Range
Power Derating
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Min.
Typ.
Max.
60 Seconds
3000
---
---
500 VDC
100
---
---
---
65
---
115VAC, Full Load
---
8
---
230VAC, Full Load
---
40
---
MIL-HDBK-217F@25℃, Ground Benign
628,000
---
---
According IEC/EN 60536
UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1 (CB-report)
IEC/EN 60335-1 recognition (CB-report, TUV certificate)
Unit
VACrms
MΩ
KHz
ms
ms
Hours
Conduction & Radiation
EN55014-2 ,EN55024
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
PFMF
Dips
Interruptions
Standards & Level
EN55011, EN55014-1, EN55022, FCC part 15
EN61000-4-2 Air ± 8kV, Contact ± 4kV
EN61000-4-3 10V/m
EN61000-4-4 ±2kV
EN61000-4-5 ±1kV
EN61000-4-6 10Vrms
EN61000-4-8 30A/m
EN61000-4-11 30% 10ms
EN61000-4-11 >95% 5000ms
Performance
Class B
A
A
A
A
A
A
A
B
Conditions
Natural Convection
+50℃ to +70℃
Min.
Max.
-25
+70
-40
+85
0.125
---
95
Natural Convection
---
260
Unit
℃
℃
W/℃
% rel. H
℃
Notes
1 Peak load lasting <30s with a maximum duty cycle of 10%, average output power not to exceed maximum power.
2 All specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless otherwise noted.
3 Ripple & Noise of PCB mounting type measured with a 1μF/50V MLCC.
4 We recommend to protect the converter by a slow blow fuse in the input supply line.
5 Other input and output voltage may be available, please contact factory.
6 That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
7 Specifications are subject to change without notice.
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2015/12/25 REV:0 Page 2 of 4