English
Language : 

AAF-05 Datasheet, PDF (2/4 Pages) Minmax Technology Co., Ltd. – fully enacpsulated module with solder pins for pcb mount
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise
Minimum Load
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
AAF-05 SERIES
AC/DC POWER MODULE 5W
Conditions
Min.
Typ.
---
---
Vin=Min. to Max. @Full Load
---
---
Io=0% to 100%
---
---
3.3V & 5VDC Output Models
---
---
0-20 MHz Bandwidth
Other Output Models
---
---
No minimum Load Requirement
Zener Diode Clamp
---
125
---
---
---
---
Foldback, auto-recovery
135
150
(long term overload condition may cause damage)
Hiccup mode, indefinite (Automatic Recovery)
Max.
±2.0
±1.0
±1.0
60
1
190
±0.05
5
---
Unit
%Vom.
%
%
mVPP of Vo
%VPP of Vo
% of Vo
%/℃
%Vout
%Inom.
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
Protection Class II
Safety Approvals (Pending)
EMC Specifications
Parameter
EMI
EMS
Conditions
Min.
Typ.
60 Seconds
3000
---
500 VDC
100
---
---
65
115VAC, Full Load
---
8
230VAC, Full Load
---
40
MIL-HDBK-217F@25℃, Ground Benign
TBD
According IEC/EN 60536
UL/cUL 60950-1 recognition(UL certificate)
IEC/EN 60950-1(CB-report)
IEC/EN 60335-1 recognition(TUV certificata,CB-report)
Conduction
Radiation
EN55014-2 ,EN55024
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
PFMF
Dips
Interruptions
Standards & Level
EN55011, EN55014-1, EN55022, FCC part 15
EN61000-4-2 Air ± 8kV, Contact ± 4kV
EN61000-4-3 10V/m
EN61000-4-4 ±2kV
EN61000-4-5 ±1kV
EN61000-4-6 10Vrms
EN61000-4-8 30A/m
EN61000-4-11 30% 10ms
EN61000-4-11 >95% 5000ms
Max.
Unit
---
VAC
---
MΩ
---
KHz
---
ms
---
ms
Hours
Performance
Class B
A
A
A
A
A
A
A
B
Environmental Specifications
Parameter
Temperature Range (operational)
Power Derating
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from
case for 10Sec.)
Conditions
Ambient
+50℃ to +70℃
Min.
-25℃
-40℃
---
Natural Convection
---
Max.
+70℃
0.125 W/℃
+85℃
95 % rel. H
260℃
Notes
1 Peak load lasting <30s with a maximum duty cycle of 10%, average output power not to exceed maximum power.
2 All specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless otherwise noted.
3 Ripple & Noise of PCB mounting type measured with a 1μF/50V MLCC.
4 We recommend to protect the converter by a slow blow fuse in the input supply line.
5 Other input and output voltage may be available, please contact factory.
6 That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
7 Specifications are subject to change without notice.
E-mail:sales@minmax.com.tw Tel:886-6-2923150