English
Language : 

MTQZ75 Datasheet, PDF (1/7 Pages) Minmax Technology Co., Ltd. – under-voltage shutdown
®
FEATURES
►Small 57.9 x 36.8 x12.7 mm Package
►Input Ranges 43-101VDC or 66-160VDC
►Meets Railway Standard EN50155 (IEC60571) and EN45545-2
►Compliance to Railway EMC Standard EN50121-3-2
►High Efficiency up to 92%
►No Minimum Load Requirement
►Operating Temp. Range -40°C to +70°C.
►Reinforced Insulation 3000 VACrms
►Under-Voltage Shutdown
►Remote On/Off
►UL/cUL/IEC/EN 60950-1 Safety Approval
►Metal Case with isolated Baseplate
►3 Years Product Warranty
MTQZ75 SERIES
DC/DC CONVERTER 75W, Railway Applications
PRODUCT OVERVIEW
The MINMAX MTQZ75 series is a new generation of high performance, convection-cooled 75W dc-dc converters designed specifically for railway
applications.They are available for the popular railway input voltages of either 72(43-101)VDC or 110(66-160)VDC.
The converters conform to railway industry transient standard EN50155 and complies also with EMC standard EN50121-3-2.
Advanced circuit topology provides a very high efficiency up to 92% which allows operating temperatures range of -40°C to +70°C. For improved heat
dissipation the modules can be supplied with a heatsink.Further product features include high, reinforced insulation,remote On/Off control, under-voltage
shutdown as well as overload and over-temperature protection.
Model Selection Guide
Model
Input
Number
Voltage
(Range)
VDC
MTQZ75-72S05
MTQZ75-72S12
72
MTQZ75-72S15 ( 43 ~ 101 )
MTQZ75-72S24
MTQZ75-110S05
MTQZ75-110S12
110
MTQZ75-110S15 ( 66 ~ 160 )
MTQZ75-110S24
Output
Voltage
VDC
5
12
15
24
5
12
15
24
Output Current
Input Current
Max.
mA
15000
6250
5000
3125
15000
6250
5000
3125
@Max. Load
mA(typ.)
1170
1132
1132
1145
766
749
749
758
@No Load
mA(typ.)
50
45
45
55
40
35
35
50
Reflected
Ripple
Current
mA(typ.)
35
35
Over
Voltage
Protection
VDC
6.2
15
18
30
6.2
15
18
30
Max. capacitive
Load
μF
25500
4400
2800
1100
25500
4400
2800
1100
Efficiency
(typ.)
@Max. Load
%
89
92
92
91
89
91
91
90
Input Specifications
Parameter
General
Input Surge Voltage (100ms. max)
Start-up Threshold Voltage
Under Voltage Shutdown
Start-up Time
Input Filter
Model
72V Input Models
110V Input Models
72V Input Models
110V Input Models
72V Input Models
110V Input Models
All Models
Min.
Typ.
Max.
Unit
Input Specifications comply to
-0.7
---
165
-0.7
---
250
---
---
43
VDC
---
---
66
---
40
---
---
63
---
---
0.35
---
S
Internal Pi Network
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2014/12/24 REV:6 Page 1 of 7